REPLACEMENT OF PARTS

• Push water valve back to disengage it from re-
versing valve.
• Unclip and remove loss of water pressure switch
from left of reversing valve assembly, 

see diagram

33.

• From below boiler, undo and remove three
screws holding reversing valve to bottom plate of
boiler. Remove complete reversing valve assem-
bly from boiler.
• Undo and remove heating return connecting
pipe and hose from rear of reversing valve assem-
bly. Fit hose to replacement reversing valve assem-
bly.
• Fit replacement reversing valve into boiler in re-
verse order to removal.

Note:

 Use new 'O' rings, retaining clip, filter and

washer provided.
• Unscrew and remove microswitch assembly from
top of replacement reversing valve assembly to
allow refitting of water valve.

Note:

 fit expansion vessel pipe and loss of water

switch to reversing valve assembly before pump,
to ensure that it is correctly located. Apply silicone
grease to all 'O' rings and hoses prior to assembly.
• Open isolating valves on flow and return con-
nections, refill, vent and pressurise boiler. Check for
leaks.

To replace reversing valve front section

• Remove pressure gauge capillary as described
previously.
• Remove pipe connections from either side of
reversing valve front section, refer to previous sec-
tion.
• Move short selector lever on front of valve to left
hand position.
• From below boiler, undo and remove single screw
holding reversing valve front plate to bottom plate
of boiler.
• Undo and remove six screws holding front sec-
tion to rear section of reversing valve, 

see diagram

34.

• Remove front plate complete with pump bracket
and then front section from reversing valve, along
with rubber sealing gasket.
• Assemble bypass valve provided and fit into hole
in underside of replacement front section. Fit 'U'
shaped retaining clip.

Note:

 Use bypass valve fitted to original front sec-

tion for guidance.
• Fit replacement front section, with gasket, to rear
section.
• Locate front plate and replace six fixing screws.
Take care to evenly tighten screws ensuring they
are not cross threaded.
• Refit pipe connections to either side of front sec-
tion using new 'O' rings provided. Apply silicone
grease to 'O' rings before fitting.
• Refit pressure gauge capillary in reverse order to
removal.
• Ensure short selector lever on front of valve is set
to right hand position.
• Open isolating valves on flow and return con-
nections, refill, vent and pressurise boiler. Check for
leaks.

To replace loss of water switch

• Drain down heating circuit of boiler only as de-
scribed in '

To replace pump'.

Note: 

It is not necessary to drain entire heating cir-

cuit to carry out this work.
• Pinch plastic cover to release retaing clips and
remove cover from switch. Pull plug lead from
switch terminals.
• Remove clip holding switch into left side of re-
versing valve assembly.
• Pull switch out of reversing valve assembly, 

see

diagram 33.

• Fit replacement switch in reverse order to re-
moval, using new 'O' ring provided and applying
silicone grease to 'O' ring before fitting.
• Reconnect plug to switch terminals.
• Open isolating valves on flow and return con-
nections, refill, vent and pressurise boiler. Check for
leaks.

To replace water valve or diaphragm (except SB
models)

• Drain down hot water circuit of boiler only as
described in '

Routine Cleaning and Inspection'.

• Remove microswitch assembly as described pre-
viously.
• Unscrew connecting nut from cold water inlet
connection, second from left on fixing jig. Keep fil-
ter and flow regulator.
• Remove clip holding connecting pipe in rear of
water valve. From below boiler, grip clip with long
nosed pliers and pull down.

Note: 

This connecting pipe is telescopic, it may be

necessary to slide back brass sleeve to facilitate
removal.

Diagram 33

Sec 059

Diagram 34

Cla 007

Содержание THEMA F 23 E

Страница 1: ...1 Heating and hot water for the professionals 01773 828100 IN WARRANTY TECHNICAL HELPLINE 01773 828400 THIS IS A CAT II2H3 APPLIANCE THEMA F Installation and Servicing Instructions...

Страница 2: ...essure switch 19 Spark generator 19 Main printed circuit board 19 Ignition printed circuit board 20 Pump 20 Temperature Pressure gauge 20 Reversing valve assembly 20 Reversing valve front section 21 L...

Страница 3: ...ec tion Alternatively the boiler is designed to allow the flue system to be connected to the top of the boiler top outlet flue connection Refer to the flue fitting instructions Electrical components h...

Страница 4: ...eating output automatically variable from kW 8 9 8 9 8 9 BTU H 30 000 30 000 30 000 to kW 23 3 18 5 23 3 BTU H 80 000 63 000 80 000 Efficiency 91 5 90 5 91 5 Heating adjustment 38 C to 90 C Expansion...

Страница 5: ...799 51214 54628 58042 61456 64871 68285 71699 75113 79552 Heat input kW 11 9 13 2 14 4 15 7 16 9 18 1 19 2 20 4 21 5 22 7 23 8 24 9 26 0 26 9 28 3 Btu h 40678 45130 49332 53481 57579 61627 65626 69575...

Страница 6: ...ressure switch 24 Gas cock A Heating return B Cold water inlet C Heating flow D Domestic hot water flow E Gas supply THEMA F 23 E 22 23 A C E 4 16 17 19 6 8 9 10 11 13 12 21 3 14 24 3 Ignition module...

Страница 7: ...to right the fixing jig comprises A Heating return with isolating valve m C Heating flow with isolating valve q drain screw r and safety valve s E Gas service cock 1 2 5 7 r p q 25 23 113 23 s A C E m...

Страница 8: ...made for filling the system at low level The use of a WRC approved filling loop is strongly recommended connected as shown in diagram 6 Safety valve discharge WARNING It must not discharge above an en...

Страница 9: ...talled immediately protect the various couplings to prevent any ingress of foreign materials e g plaster paint etc Terminal position The minimum acceptable spacings from the ter minal to obstructions...

Страница 10: ...age boiler upper part onto the hook see dia gram 9 Allow the boiler to seat down onto support plate see diagram 10 Fit filter and washers strictly adhering to the se quential order and directions show...

Страница 11: ...aged Calculation of flue cutting lengths Measure wall thickness e mm For side flues measure distance from inside face of side wall to centre line of flue and subtract 176 mm for right hand flue or sub...

Страница 12: ...e outer end of pipe A see diagram 16 Fit outer pipe A into wall with groove to the outside Pull pipe inwards to bring rubber sealing collar hard up against external wall see diagram16 Fit internal pla...

Страница 13: ...ue and subtract 205 mm for both right and left hand flues to get dimension a mm Refer to table 1 for cutting lengths of both inner and outer flue pipes for each of the various flue options available I...

Страница 14: ...arning This appliance must be wired in accord ance with these instructions Any fault arising from incorrect wiring cannot be put right under the terms of the Saunier Duval guarantee Time clock A mecha...

Страница 15: ...wing the instructions given in the User Instruc tions set boiler to run in central heating mode Set boiler thermostat for maximum temperature and check that any external controls if fitted are calling...

Страница 16: ...inue to run The boiler will be ready to operate when the fault has been cleared In case of power supply failure The boiler no longer operates As soon as power supply is restored the boiler will be aut...

Страница 17: ...ss The THEMA F 23 E has a built in bypass This must be adjusted according to the requirements of the sys tem refer to the flow rate pressure curve diagram 3 The boiler is supplied with the built in by...

Страница 18: ...e insulation material on inside faces of combustion chamber Cleaning the burner Pull off leads to ignition electrode Pull off lead to flame sense electrode Unscrew and remove screw holding earth lead...

Страница 19: ...rnal controls connector from mount ing bracket Undo two screws securing microswitch assembly to reversing valve assembly see diagram 29 Remove microswitch assembly from reversing valve Fit replacement...

Страница 20: ...onto inlet connection on replacement pump Fit replacement pump in reverse order to re moval Note Apply silicone grease to pump outlet con nection O ring before assembly Refit pump electrical connecti...

Страница 21: ...it U shaped retaining clip Note Use bypass valve fitted to original front sec tion for guidance Fit replacement front section with gasket to rear section Locate front plate and replace six fixing scre...

Страница 22: ...f water valve When clip is fitted check con nection by pushing pipe back away from water valve Refit telescopic connecting pipe to inlet of wa ter valve after applying silicone grease to O ring Fit re...

Страница 23: ...mini mum clearance of 400mm on one side of the boiler and that no vertical pipework passes between boiler and wall on that side Drain down the heating circuit of the boiler only as described in To rep...

Страница 24: ...and Inspection Pull off lead from flame sense electrode Unscrew and remove screw holding earth lead to flame sense electrode Unscrew and remove screw holding flame sense electrode onto burner Fit rep...

Страница 25: ...14 8 14 9 6 8 6 6 6 4 6 2 6 3 2 2 2 1 9 1 9 2 8 4 8 3 8 2 8 1 12 1 12 2 P THEMA F 23 E PCB N L P Ex EV1 EV TRA 6 14 6 15 6 11 CTN TH V3V TA K5 K4 Pr FL Ra FA Al 6 12 6 9 13 2 13 3 13 1 13 4 14 1 14 2...

Страница 26: ...a logical step by step pro cedure starting at the beginning of the appropriate fault finding chart WARNING Always isolate the boiler from the electri cal supply before carrying out any electrical rep...

Страница 27: ...NOT RUNNING FAN NOT RUNNING Replace main PCB YES CHART 4 NO NO Is pump jammed Replace pump motor NO Free pump Replace main PCB Is fan jammed Replace fan NO SPARE PARTS When ordering spare parts quote...

Страница 28: ...28 108198 B 06 98...

Отзывы: