SECTION 3 - Interface Specifications
Rev C
50
SATO M-8400RV Service Manual
3-4 RS232C Serial Interface (Cont.)
Cable Requirements
HOST
INTERCONNECTION
PRINTER
FG
1 FG (Frame Ground)
TD
3 RD (Receive Data)
4 RTS (Request to Send)
5 CTS (Clear to Send)
6 DSR (Data Set Ready)
*
20 DTR (Data Terminal Ready)
SG
7 SG (Signal Ground)
7KLVFRQQHFWLRQDWWKHKRVWVLGHRIWKHLQWHUIDFHZRXOGGHSHQGXSRQWKHSLQWKDWLV
EHLQJXVHGDVWKH5HDG\%XV\VLJQDOE\WKHGULYLQJVRIWZDUH7\SLFDOO\RQD3&LWZRXOG
EHHLWKHU&76SLQRU'65SLQRQD'%FRQQHFWRU
Data Streams
2QFHWKHIORZFRQWUROPHWKRGKDVEHHQFKRVHQIRUWKH56&LQWHUIDFHWKHGDWDVWUHDP
PXVWEHVHQWLQDVSHFLILFPDQQHU7KH67;D]QG(7;&RQWUROFKDUDFWHUVPXVWIUDPHWKH
GDWDVWUHDP
<STX><ESC>A..Job#1..<ESC>Z<ETX><STX><ESC>A..Job#n..<ESC>Z<ETX>
127($OOFKDUDFWHUVLQFOXGLQJ67;(6&DQG(7;DUHLQ$6&,,