SECTION 2 – Configuration
Rev C
37
SATO M-8400RV Service Manual
Sensor Threshold Level
7KH059SULQWHUGHWHUPLQHVWKHORFDWLRQRIWKHOHDGLQJHGJHRIWKHODEHOE\
PHDVXULQJWKHGLIIHUHQFHEHWZHHQOLJKWOHYHOVZKHQLWVHHVHLWKHUDODEHOHGJHRUDEODFN
´,0DUNµ7KLVDGMXVWPHQWDOORZV\RXWRPDQXDOO\VHWWKHWKUHVKROGYROWDJHOHYHO
EHWZHHQWKHPD[LPXPDQGPLQLPXPOLJKWOHYHOV',3VZLWFK'6:VHOHFWVWKHVHQVRU
W\SH,I
'6:
LVLQWKH2))
SRVLWLRQWKHVHWWLQJZLOOEHIRUD6HH7KUXRU*DS
VHQVRUDQGWKH/&'ZLOOGLVSOD\´
*$3
µRQWKHWRSOLQHDORQJZLWKWKHFXUUHQWVHWWLQJ,I
'6:
LVLQWKH
21
SRVLWLRQWKH/&'ZLOOGLVSOD\´,0DUNµRQWKHWRSOLQHZLWKLWV
FXUUHQWVHWWLQJ,IWKHYDOXHHQWHUHGIRUWKHERWWRPOLQHVHWWLQJLV´9µWKHQWKHSULQWHU
ZLOODXWRPDWLFDOO\FDOFXODWHWKHVHWWLQJZKHQWKHILUVWODEHOLVIHGDIWHUWKHSULQWHULV
SRZHUHGRQRUWKHKHDGLVFORVHG7KHUHDUHVRPHLQVWDQFHVZKHUHWKHDXWRPDWLFDOO\
FDOFXODWHGYDOXHPXVWEHDGMXVWHGWRHQVXUHUHOLDEOHODEHOIHHGLQJVXFKDVZKHQWKH
EDFNLQJRSDFLW\RUWKHUHIOHFWDQFHRIWKH´,0DUNµYDULHVVLJQLILFDQWO\ZLWKLQDUROORI
ODEHOVRUEHWZHHQODEHOUROOV,QWKHVHLQVWDQFHVWKHYDOXHVKRXOGEHVHWXVLQJWKH
IROORZLQJSURFHGXUHV
*$36(1625
:KHQVHWWLQJWKH´JDSµWKUHVKROGWKHYROWDJHVKRZQRQWKHWRSOLQH
RIWKHGLVSOD\PXVWEHPHDVXUHGZLWKQRWKLQJEXWWKHEDFNLQJSDSHULQWKHVHQVRUDQG
WKHQDJDLQZLWKDODEHOVWLOODWWDFKHGWRWKHEDFNLQJ7KHIRUPXODWREHXVHGIRUVHWWLQJ
WKHWKUHVKROGLV
+LJK9ROWDJH/HYHO/RZ9ROWDJH/HYHO[ 6WDUW9DOXH
7RDFFHVVWKLVVHWWLQJSHUIRUPWKHVWHSV
STEP PROCEDURE
,QVHUWDODEHOVWLOODWWDFKHGWRWKHEDFNLQJLQWRWKHVHQVRUDQGFORVHWKH
/DEHO+ROG'RZQ5HFRUGWKHYROWDJHVKRZQRQWKHWRSOLQHRIWKH/&'
SDQHO7KLVOLQHVKRXOGKDYHWKHPHVVDJH´*$3µRQWKHWRSOLQH',3
VZLWFK'6: 2))0DNHVXUHWKHODEHOLVDOOWKHZD\XQGHUWKH
VHQVRUDQG6HH7KURXJK6HQVRULVDOLJQHGRYHU\RXUODEHO