SATEL
SZW-02
4
Press
to confirm changes.
operating time in monostable mode
– after the function is started, the green LED will
be flashing rapidly. Use the keypad to enter the length of time for which the relay output
is to remain in the monostable mode (1...999 seconds). Press
to confirm
changes.
keypad backlighting mode
– after the function is started, press:
– always off;
– automatically on (after pressing any key);
– always on.
Press
to confirm changes.
restore default settings
4 Factory default settings
Factory default codes:
user: 1234,
service: 12345.
Relay output operating mode: monostable.
Relay output type: NO.
Operating time in monostable mode: 5 seconds.
Keypad backlighting mode: automatic.
5 Specifications
Supply voltage .......................................................................................................................
9…16 VDC
Standby current consumption ........................................................................................................ 18 mA
Maximum current consumption ..................................................................................................... 58 mA
ALM output (OC type) ..................................................................................................... 30 mA / 12 VDC
Relay output ........................................................................................................................ 2 A / 28 VDC
Weight ............................................................................................................................................. 156 g
The declaration of conformity may be consulted at www.satel.eu/ce