SP-6500 • SD-6000
SATEL
LED
- input to control the LEDs used as indicators / to reset the acoustic signaling
limiting function. Connect it to the suitably programmed output of the control panel
(e.g. armed status indicator).
TMP
- tamper output (NC). Connect one terminal to the control panel zone programmed
as tamper, and the other to the control panel common ground.
STMP
- tamper input – the siren tamper switch is connected to the terminals.
SP
- terminals to which the piezoelectric transducer [SP-6500] or dynamic horn
[SD-6000] is connected.
Siren configuration pins
- jumper on; - jumper off
LED INT/EXT
Allow you to set how the LEDs used as indicators are to be controlled.
The LEDs used as indicators show that power supply is available (inner control).
The LEDs used as indicators are controlled by means of the LED input (outer
control).
FLASH/LIGHT
Allow you to set how the LEDs used as indicators are to operate.
The LEDs used as indicators are blinking when active.
The LEDs used as indicators are lit when active.
2LED/1LED
Allow you to set the number of LEDs used as indicators.
The indicator function is performed by two LEDs.
The indicator function is performed by one LED.
LOUDNESS H/L
Allow you to set the acoustic signal volume.
Maximum loudness of the acoustic signal.
Normal loudness of the acoustic signal.
LIMIT SIGN.
Allow you to enable / disable the acoustic signal limiting function. When the function is
enabled, the status of TIME 0 and TIME 1 pins is ignored, the acoustic signaling lasts up to
60 seconds and can only be triggered 3 times (a time of at least 40 seconds must elapse
between the consecutive alarms). The alarm counter will be reset after the LED input status
is changed (the LED input polarity being irrelevant).
The acoustic signal limiting function is enabled.
The acoustic signal limiting function is disabled.
TIME 1
TIME 0
The two pairs of pins allow you to set the cut-off time of acoustic signaling.
1 minute.
5 minutes.