background image

SATEL 

SP-6500 • SD-6000 

4.  Place the enclosure base on the wall and mark the location of mounting holes (see 

Fig. 2). Be sure to take into account the tamper mounting hole. 

5.  Drill the holes for wall plugs (screw anchors). 
6.  Run the wires through the hole in the enclosure base (see Fig. 2) 
7.  Using wall plugs (screw anchors) and screws, fasten the enclosure base to the wall (the 

wall plugs and screws are included in the siren delivery set). 

8.  Secure the electronics module in the enclosure base. 
9.  Connect the siren terminals with wires to the control panel terminals. 
10. Using jumpers, configure the siren. 
11. If a battery is to be installed in the siren, secure the battery with the holders provided for 

this purpose, and then connect leads to the battery (the red lead to the positive terminal, 
the black lead to the negative terminal). After connecting the battery, two LEDs will start 
blinking rapidly. 

12. Replace the siren cover, close the cover and then lock it with the screw. 
13. Power on the control panel. When the two LEDs stop blinking rapidly, you can test the 

siren for correct functioning. In order to test the siren you can use the output test function, 
which is available in some control panels, or you can trigger an alarm for testing 
purposes. 

Mounting the hinges in other than standard factory position 

 

If the cover is to open in other direction than the standard factory one, open the cover and: 
1.  Detach the hinges and remove the cover. 

Содержание SP-6500

Страница 1: ...f using two LEDs as indicators and customize their functionality to the user s needs Optional operation with a backup battery Weatherproofed electronic circuit Tamper protection in 2 ways cover remova...

Страница 2: ...m Weight SP 6500 1160 g SD 6000 1530 g The declaration of conformity may be consulted at www satel eu ce 3 Description Fig 1 shows the SP 6500 siren with cover open enclosure base piezoelectric transd...

Страница 3: ...two LEDs that the alarm signaling cannot be triggered If the signaling must be triggered for test purposes immediately after start up of the siren skipping the 30 second delay do as follows 1 Remove...

Страница 4: ...ed as indicators are to operate The LEDs used as indicators are blinking when active The LEDs used as indicators are lit when active 2LED 1LED Allow you to set the number of LEDs used as indicators Th...

Страница 5: ...tatus 12 V DC voltage s triggered wh oltage is remo is applied to the input en 12 V DC v Optical signaling is triggered when 0 V voltage is removed inactive status 0 V voltage is applied to the input...

Страница 6: ...e installed on the wall high above the floor at a hard to access location so as to minimize the risk of tampering 1 Undo the cover locking screw you do not have to remove it completely and holding the...

Страница 7: ...be installed in the siren secure the battery with the holders provided for this purpose and then connect leads to the battery the red lead to the positive terminal the black lead to the negative term...

Страница 8: ...5 3 Insert the moving parts of hinges in the holders on the left hand side to open the cover to the right or on the right hand side to open the cover to the left see Fig 6 and Fig 7 SATEL sp z o o ul...

Отзывы: