INT-VG
SATEL
buttons for manual control of the module:
REC
– recording the message;
PLAY
– playing back the message;
MSG. NO
– selecting the message number.
microphone.
2.1 Setting the DIP-switches
Switches 1-5
The DIP-switches from 1 to 5 are used to set the address. The switches have numbers
assigned to them. In the OFF position, the value is 0. The numbers assigned to the switches
in ON position are presented in the table 2. The sum of these numbers is the address set.
The module must have an individual address set in it, i.e. the address must be different from
that in the other devices connected to the control panel bus. Figure 2 shows examples of the
address setting. The address 23 [17h] must be set in the module connected to the VERSA
control panel.
Switch (ON position)
1
2
3
4
5
Number
1
2
4
8
16
Table 2.
Switch 6
Position of the switch 6 is irrelevant.
Switch 7
Use the switch 7 to select the operating mode of the device:
OFF
–
INT-VG
– full functionality,
ON
–
CA-64 SM
– handling of notification messages only.
The INT-VG module is supported by the INTEGRA control panels with firmware version 1.10
(or newer) and the VERSA control panels with firmware version 1.02 (or newer).
The CA-64 SM synthesizer is supported by the INTEGRA and VERSA control panels with
any firmware version.
Only one module operating as INT-VG can be connected to the control panel.
If you need more than 16 notification messages, the second module connected to the
control panel must operate as CA-64 SM. The following control panels can notify of
events by means of 32 voice messages: INTEGRA 128, INTEGRA 128 Plus and
INTEGRA 256 Plus.