background image

The INT-KWRL2 wireless keypad enables operation and programming of the INTEGRA and 
INTEGRA Plus control panels with firmware version 1.19 (or newer). The device is designed 
for work within the ABAX 2 / ABAX two-way wireless system. This manual applies to the 
keypad with firmware version 3.00 (or newer), which is supported by: 

  ABAX 2: ACU-220 / ACU-280 controller, 

  ABAX: ACU-120 / ACU-270 controller (firmware version 5.04 or newer). 

The ABAX 2 / ABAX controller must be connected to the expander bus (controller 
terminals CKE and DTE) and the keypad bus (controller terminals CKM and DTM) of 
the INTEGRA / INTEGRA Plus alarm control panel. 

In the ACU-220 / ACU-280 controller, switches 9 and 10 must be set in OFF position. 

In the ACU-120 / ACU-270 controller, switch 8 must be set in OFF position. 

The keypad is not supported by the ARU-100 and ARU-200 radio signal repeaters or 
by the INTEGRA 128-WRL control panel. 

 

 

Fig. 1. INT-KWRL2 keypad. 

 

Содержание INT-KWRL2

Страница 1: ...INT KWRL2 Wireless keypad Firmware version 3 00 int kwrl2_en 04 19 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel pl...

Страница 2: ...y improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Plea...

Страница 3: ...ABAX ACU 120 ACU 270 controller firmware version 5 04 or newer The ABAX 2 ABAX controller must be connected to the expander bus controller terminals CKE and DTE and the keypad bus controller terminals...

Страница 4: ...s state periodical communication Additional communication takes place when the keypad is in use in the case of keypad tamper when the controller is sending commands to the keypad wake up and trigger C...

Страница 5: ...e existing rules for environment protection The keypad is designed for indoor installation The place of installation should be readily accessible to the system users When selecting the installation lo...

Страница 6: ...ure Fig 2 7 Place the enclosure base against the wall and mark location of the mounting holes 8 Drill the holes in the wall for wall plugs anchors 9 Using wall plugs anchors and screws secure the encl...

Страница 7: ...ified as INT KWRL Simultaneous operation of the keypad by the ABAX 2 and ABAX controller is not possible 3 1 1 DLOADX program You can add wireless keypad in the Structure window Hardware tab after cli...

Страница 8: ...see Fig 4 p 7 1 Click on the Read button to read the data related to wireless keypads from the controller 2 Click on the wireless keypad you want to remove 3 Click on the Remove device button 4 The Co...

Страница 9: ...will also be signaled when the keypad is in the sleep mode If you enter 0 the keypad will not be woken up automatically If a value different from 0 is preset for the Wake up parameter the keypad will...

Страница 10: ...ansion modules branch keypad name see Fig 5 LCD keypad Service mode Structure Hardware LCD keypads Settings keypad name Fig 5 DLOADX program keypad settings stored in the control panel Keypad tab 4 2...

Страница 11: ...feature Bypass time Chime bps time time during which the CHIME signal will be disabled after violation of the zone which disables the signaling time is counted from the zone restore If you enter 0 th...

Страница 12: ...p arm if this option is enabled the LED goes off after all managed by keypad partitions are armed if the option is disabled the LED goes off after just one of the partitions is armed Sign new trouble...

Страница 13: ...volume level of the entry delay beeps Volume exit delay volume level of the exit delay beeps Volume fire volume level of the fire alarm beeps Volume alarm volume level when signaling burglar panic and...

Страница 14: ...ogram keypad settings stored in the control panel State inspections tab Zone state Zone characters You can define the symbols which will be used to illustrate the state of zones on the display Partiti...

Страница 15: ...r Door to open if presenting the card or holding it is to open a door you must indicate the door supervised by the access control module or the 101 Card read expander type output Fig 9 DLOADX program...

Страница 16: ...on to waking up the keypad from sleep pressing a key will also have other consequences as appropriate for the given key The keypad will treat each key pressing exactly in the same way When in the wake...