SATEL ASD-200
7
11. Replace the thermistor cover.
12. Secure the electronics board with the optical chamber in the cover mounting catches. The
board must be mounted so that the LED coincides with the light guide.
13. Re-install the battery.
14. Replace the detector cover.
15. Press the test / reset button (Fig. 1). Fire alarm should be triggered.
7
Battery replacement
The used batteries must not be discarded, but should be disposed of in
accordance with the existing rules for environment protection.
When the detector indicates low battery (3 short flashes of the LED and 3 short beeps every
30 seconds), the battery must be replaced.
1. Start the service mode in the control panel (if the controller is connected to a SATEL
alarm control panel).
2. Turn the cover counter-clockwise (Fig. 5) and remove it (Fig. 6).
3. Remove the discharged battery.
4. Install a new CR123A 3 V lithium battery.
5. Replace the detector cover.
6. Press the test / reset button (Fig. 1). Fire alarm should be triggered.
8
Specifications
Operating frequency band ...................................................................868.0 MHz ÷ 868.6 MHz
Radio communication range (in open area)
ABAX 2
ACU-220 .............................................................................................. up to 2000 m
ACU-280 .............................................................................................. up to 1200 m
ABAX.............................................................................................................. up to 500 m
Battery ................................................................................................................... CR123A 3 V
Battery life expectancy.......................................................................................... up to 2 years
Standby current consumption ...........................................................................................30 µA
Maximum current consumption........................................................................................50 mA
Static response temperature.............................................................................................. 54°C
Operating temperature range.................................................................................... 0°C...55°C
Maximum humidity.......................................................................................................... 93±3%
Dimensions ......................................................................................................... ø108 x 54 mm
Weight............................................................................................................................... 170 g