4 AOCD-250
SATEL
4
3
9. Mount the enclosure base directly to the wall (Fig. 5) or to the angle bracket screwed
down to the wall (Fig. 6). Wall plugs and screws are delivered with the detector. For the
hole designated by letter A on the figures 5 & 6, use the smaller screw. Fig. 7 shows the
possible ways of detector installation (the detector can also be mounted on the adjustable
brackets, BRACKET A and BRACKET B, offered by SATEL).
If the detector is to meet the requirements of EN50131 standard for Grade 3, it must
not be mounted on any bracket.
6
5
10. Fasten the electronics board.
11. Replace the cover.
12. Configure the detector settings (sensitivity of PIR sensor, sensitivity of microwave
sensor). For description on how to configure the detector, refer to the ABAX controller
manual or the INTEGRA / VERSA / VERSA Plus / VERSA IP control panel programming
manual.
7