Red RQ value
The embedded power sensor
needs to be calibrated. Can
only be red when RF Detector
Bandwidth in the satellite
preset is set to 0 (not
recommended).
Set RF Detector bandwidth
in as seen in Figure 33.
Or:
1.
Move the terminal to an
open space with free line of
sight towards open sky.
Increase or decrease
elevation angle to an angle
that is more than 12
degrees away from nominal
elevation towards the
current selected satellite.
Make sure the terminal is
pointing towards open sky
at this point. Otherwise
choose a different
elevation/azimuth/location.
2.
Wait 3 seconds, see the
RQ-value turn white. If the
value is not turning white,
make sure that the
elevation angle is more
than 12 degrees away from
the elevation angle of the
current selected satellite.