Accessories (Options)

Product

Order No.

Data printer

YDP20-0CE

with date/time, statistics evaluation,
transaction counter functions and LCD 

– Paper (5 rolls)

6906937

Remote display

– reflective

YRD02Z

– for overhead projectors, transmissive

YRD13Z

External rechargeable battery pack

YRB08Z

with external battery charger (hours of operation: 
20 or 40, depending on balance model)

SartoConnect data transfer program for interfacing 

YSC01L

a Sartorius balance to a PC with a Windows 95/98 or NT 
operating system

This software enables you to transfer the data recorded 
by your balance to any PC application program (e.g., Excel).

RS-232C interface cable 

for PC connection, 25-pin

7357312

COM data interface for PC connection, 9-pin

7357314

Universal remote control switch:

Foot switch with T-connector 

YFS01

Hand switch with T-connector

YHS02

T-connector YTC01

for connecting 2 peripheral devices

Carrying case

– for models with a readability 

>

1 mg

YDB01TE

Содержание M-Power AZ124

Страница 1: ...98648 018 69 Operating Instructions Sartorius M power Electronic Analytical and Precision Balances and Precious Metal Scales...

Страница 2: ...e electromagnetic disturbance can cause the readout value to change Once the disturbance has ceased the instrument can be used again in accordance with its intended use Setting up the Balance Warning...

Страница 3: ...a round weighing pan AC adapter plug type Additionally supplied with AZ214 AZ124 AZ64 models Shield ring Shield plate Dust cover Installation Instructions When choosing a location to set up your bala...

Страница 4: ...the order given Draft shield base place it on the balance so that the edge for fitting the glass draft shield faces upwards and turn it until it is firmly in place Pan support Weighing pan Glass draft...

Страница 5: ...outlet The ground terminal is connected to the balance housing which can be additionally grounded for operation Selecting the Line Voltage Mains Voltage Optional Use the following original AC adapters...

Страница 6: ...ly on models AZ3102 AZ1502 G Turn the 2 front feet as shown here in the illustration until the air bubble is centered in the level indicator In most cases this will require several adjustment steps An...

Страница 7: ...ress this key to send readout values to the built in data interface 7 Start an application program Position Designation 8 Delete Clear Function This key is generally used to cancel functions Quit appl...

Страница 8: ...Warmup Time To ensure accurate results the balance must warm up for 30 minutes before operaion Only after this time will the balance have reached the required operating temperature Example Basic weig...

Страница 9: ...an use any of the following weight units to calibrate adjust g kg lb menu code 1 4 x You can block calibration adjustment of the balance Select menu code 1 5 3 Example Step Key or instruction Display...

Страница 10: ...ample Step Key or instruction Display Printout 1 Place an empty container on 65 0 g the balance 2 Tare the balance t 0 0 g 3 Add the first component 120 5 g 4 Store the first component weight v 0 0 gN...

Страница 11: ...ted parts 174 pcs here 174 pcs 6 Display weight v 574 2 g 7 Display quantity v 174 pcs 8 Unload the balance 0 pcs 9 Delete the reference value c 10 Repeat the procedure starting from step 5 if desired...

Страница 12: ...g the Balance Example Determine an unknown percentage store the weight on the balance as a reference percentage Menu Application program Weighing in Percent menu code 2 1 5 Menu Reference percentage 1...

Страница 13: ...s 3 3 4 50 subweighs 3 3 5 100 subweighs See also Configuring the Balance Example Determine the weight of a sample in extremely unstable ambient conditions by calculating the average of 10 subweighing...

Страница 14: ...215074700 ozt 1 7 8 3 1 8 Hongkong taels 0 02671725000 tlh 1 7 9 3 1 9 Singapore taels 0 02645544638 tls 1 7 10 3 1 10 Taiwanese taels 0 02666666000 tlt 1 7 11 3 1 11 Grains 15 43235835000 GN 1 7 12 3...

Страница 15: ...briefly 1 To navigate within a menu t repeatedly 2 level the last menu option is followed by the first option 9 1 3 Select the 2nd menu level p 1 1 4 Select the 3rd menu level p 1 1 2 o 5 In Menu Leve...

Страница 16: ...ght Units 1 8 Display accuracy 1 8 1 Standard resolution 1 8 4 Single scale interval 2 Application 2 1 Program selection See the desired application programs program description 3 Application 3 1 Weig...

Страница 17: ...1 Line format of printout 7 1 1 Without data ID Codes applications 7 1 2 With data ID Codes programs 7 2 ISO GLP compliant 7 2 1 Off printout 7 2 2 For calibration adjustment only 7 2 3 Always on 7 3...

Страница 18: ...enu codes see Configuring the Balance GLP compliant record menu code 5 5 2 ISO GLP compliant record after calibra tion adjustment only menu code 7 2 2 or ISO GLP compliant record always on menu code 7...

Страница 19: ...ng result Dotted line 17 Jan 2010 10 20 Date time end of measurement Name Field for operator signature Blank line Dotted line ISO GLP compliant printout for external calibration adjustment Dotted line...

Страница 20: ...GND Pin 15 Universal remote switch Pin 16 Not connected Pin 17 Not connected Pin 18 Not connected Pin 19 Not connected Pin 20 Data Terminal Ready DTR Pin 21 Internal ground GND Pin 22 Not connected Pi...

Страница 21: ...only when zero balance is loaded is displayed e 09 When gross value zero no tare Tare the balance e 10 The t key is blocked when Press c to clear the tare there is data in the second tare memory and...

Страница 22: ...ent soap G After cleaning wipe down the balance with a soft dry cloth Removing and Cleaning the Weighing Pan G Lift up and remove the weighing pan together with the pan support by gripping them from u...

Страница 23: ...n Goettingen Germany Maintenance and repair work may only be performed by service technicians who are authorized by Sartorius Instructions for Recycling To ensure adequate protection for safe shipment...

Страница 24: ...ation to ambient conditions By selection of 1 of 4 optimized filter levels Display update depends on the filter level selected s 0 2 0 4 0 2 0 4 0 2 0 4 External calibration weight g 200 E2 100 E2 50...

Страница 25: ...e average s 3 3 2 5 2 5 2 5 Adaptation to ambient conditions By selection of 1 of 4 optimized filter levels Display update depends on the filter level selected s 0 2 0 8 External calibration weight g...

Страница 26: ...onse time average s 2 5 2 2 2 1 5 Adaptation to ambient conditions By selection of 1 of 4 optimized filter levels Display update depends on the filter level selected s 0 2 0 8 External calibration wei...

Страница 27: ...SartoConnect data transfer program for interfacing YSC01L a Sartorius balance to a PC with a Windows 95 98 or NT operating system This software enables you to transfer the data recorded by your balan...

Страница 28: ...stainless steel 641211 300 ml weight 22 g aluminum 69641304 110 ml 90 mm d aluminum 69GP0003 270 ml weight 62 g 137 mm d stainless steel YWP03G 62 mm d stainless steel 6910848 85 ml 70 mm d aluminum...

Страница 29: ...29...

Страница 30: ...erved No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius The status of the information specifications and illustra...

Отзывы: