![Sartorius la series Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/sartorius/la-series/la-series_operating-instructions-manual_1199748006.webp)
Tare Memory, Calculated Values:
The symbols displayed here indicate
when there is a value in one of the tare
memories or when the value shown is a
result of calculation rather than direct
measurement.
These symbols are as follows:
a
Calculated value
s
1
Net value | tare memory
s
2
used by an application program
(e.g., formulation, second tare
memory)
Application Pictograms:
The pictograms displayed here indicate
the application(s) selected. The pic-
togram is displayed inversely (white on
a black background) when the corre-
sponding application is active.
For example, the following symbols may
be displayed simultaneously:
A
The counting application is active
H
Checkweighing is also active
S
T
Data record
Text Line:
Additional information is displayed here
(e.g., operator guidance prompts, name
of the active program, etc.)
Soft Key Labels:
The current functions of the soft keys
above the function keys (arrow keys)
are indicated here; during calibration |
adjustment, this line shows up- and
down-arrows (
Q
and
q
) for selecting
calibration and adjustment functions.
5
Display for Menu Parameter Settings
(Setup)
This display is divided into three sections.
Status Line:
The status line of shows the function
of the display screen page. In the Setup
menu, the current menu “path” is
shown here.
Setup Menu Example: “Balance/scale
functions”:
Input and Output Window
This window contains either detailed
information (e.g., on the active
application) or a pick list. A selected
item is displayed inversely (white
characters on a black background).
You can also enter information in an
active field in this window using the
alphabetic and numeric keys.
Setup Menu Example,
“Device parameters, Adapt filter”:
The following symbol may be displayed
in the input and output window:
d
this symbol marks the saved
menu setting
Soft Key Labels
See the description “Function Keys
(Soft Keys)” on the previous page
Minimum vibration
o Normal vibration
Strong vibration
Extreme vibration
SETUP BAL.FUNC.
Line for Operating State
Input and Output Window
Soft Key Labels
To set a parameter:
G
Press the
Q
or
q
soft key repeatedly
until the desired setting is selected
(displayed inversely)
G
Confirm your selection:
press the
l
soft key
To change the numeric value of
a parameter:
G
Press the
Q
or
q
soft key repeatedly,
if necessary, until the desired setting is
selected (displayed inversely)
G
Enter a new value or character:
use the
0 1
…
9 .
keys
or the
a
key and enter the desired
letters
G
Confirm your selection:
press the
l
soft key
To exit Setup: press the
oo
soft key
Input
Bar Code Scanner or Keyboard Input
You can use a bar code scanner or an
external keyboard to input alphanumer-
ic values. These inputs are processed in
the same manner as keypad inputs on
the display and control unit of the bal-
ance. Bar code and keyboard inputs are
only displayed; they cannot activate any
function.
To assign a bar code scanner or
keyboard input to a function, press one
of the following soft keys:
– Lot
– Samples
– Measured values
– Sample number
– Tare value
– Initial weight
– Backweighed value
– Sample ID
Foot or Hand Switch Input
You can connect a foot switch or a
hand switch to the balance to have this
device perform a keypad function (such
as
c
or
w
).
PC Input
You can use a computer to control
the functions of the weighing cell and
display and control unit via the commu-
nications port (see the “Data Output
Function” section in the chapter
entitled “Operation”).