![Sartorius combics 1 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/sartorius/combics-1/combics-1_operating-instructions-manual_1199617026.webp)
Neutral Measurement
Z
nm
When the Neutral Measurement
application is selected, you can use your
weighing instrument to measure the
length, surface and volume of parts that
have roughly the same specific weight.
The
o symbol is displayed as the weight
unit.
Features:
– Store the weight on the weighing
instrument as reference weight
– Enter reference weight using a bar code
scanner
– Enter tare weight using a bar code
scanner
– Toggle the display between weight
and calculated value by pressing
w
– Info mode for display of reference
weight by pressing
w
(> 2 sec)
To calculate the result correctly, the
average weight of a reference quantity
must be known (in the example below,
the reference is 1 meter of electrical
cable). There are 2 ways to do this with
the Combics:
– By placing the number of parts defined
for the reference value on the weighing
instrument and pressing
O
to store
the average piece weight.
The reference value is shown in the
numeric display, and can be changed
by pressing
r
.
How the reference weight is calculated
depends on the menu setting for reso-
lution (3.9). Either the value is rounded
off in accordance with the display
resolution, or the display resolution is
increased 10-fold (+1 decimal place) or
100-fold (+ 2 decimal places), or maxi-
mum internal resolution is applied.
– By entering the reference weight (i.e.,
the weight of one piece) using a bar
code scanner (menu setting: “Setup>
Bar code > Store value as reference
(
ref
)"). In this case, the value is stored
as a reference automatically, without
pressing the
O
key.
This value remains active in the reference
memory until you delete it by pressing
c
, overwrite it or until you select
a different application. It also remains
stored after you switch off the Combics.
Application Parameters: Neutral Measurement
3. 5.
Minimum Load for Automatic Taring
and Automatic Printing
3. 5. 1 * 1 digit
3. 5. 2
2 digits
3. 5. 3
5 digits
3. 5. 4
10 digits
3. 5. 5
20 digits
3. 5. 6
50 digits
3. 5. 7
100 digits
3. 5. 8
200 digits
3. 5. 9
500 digits
3. 5.10
1000 digits
3. 6.
Minimum Load for Initialization
3. 6. 1 * 1 digit
3. 6. 2
2 digits
3. 6. 3
5 digits
3. 6. 4
10 digits
3. 6. 5
20 digits
3. 6. 6
50 digits
3. 6. 7
100 digits
3. 6. 8
200 digits
3. 6. 9
500 digits
3. 6.10
1000 digits
3. 7.
Automatic Taring:1st Weight Tared
3. 7. 1 * Off
3. 7. 2
On
3. 8.
Start Application with Most Recent
Application Data when Combics
is Switched On
3. 8. 1
Automatic (on)
3. 8. 2 * Manual (off)
3. 9.
Resolution for Calculation
of Reference Value
3. 9. 1 * Display resolution
3. 9. 2
Display reso 1
decimal place
3. 9. 3
Display reso 2
decimal places
3. 9. 4
Internal resolution
3.10. Decimal Places for Display of Results
3.10. 1 * None
3.10. 2
1 decimal place
3.10. 3
2 decimal places
3.10. 4
3 decimal places
3.11. Storage Parameter
3.11. 1* At stability
3.11. 2
At increased stability
3.13. Reference Weighing Instrument
3.13. 1* Off
3.13. 2
WP1
3.13. 3
WP2
26