AFFILIATION
Connect the unit only to a grounding socket outlet with an earthing and a 230 volt connection.
Before connecting the device, make sure that the voltage and frequency of the power supply correspond
to the information on the nameplate! Other voltages can lead to overheating of the device!
If you have connected the unit, wait about one hour to allow the interior to cool down
sufficiently before loading it with goods.
After delivery or transport of the device, do not connect it until the device has been idle
for at least 24 hours. This is absolutely necessary so that the coolant can collect in the
compressor.
After a power failure or if the device has been disconnected from the power supply, wait
at least 5 minutes before reconnecting and starting up the device!
If the unit is restarted immediately after it has been switched off, the fuse may trip and
interrupt the current flow. In addition, the compressor may be overloaded and damaged.
ADJUST TEMPERATURE
The temperature can be set from +2 °C to +10 °C. To set the temperature, press the SET button on the
control panel of the thermostat. The currently set temperature is displayed and can now be controlled
using the UP and DOWN buttons. Press the SET button again to complete the operation. After a short
moment, the current temperature in the barcooler is displayed again.
Excessive lowering of the temperature can lead to excessive power consumption and should be avoided.