TA2020B & IR2110B Installation Guide 

1 Introduction 

The TA2020B and IR2110B facilitate the transmission of data over ISDN networks.  

The units can be configured either by using commands entered at the serial port (much 
like a modem), or via the built-in Web interface. We recommend that you use the Web 
interface whenever possible. 

1.1 Front Panel Features 

The front panel of the unit incorporates number of LED indicators depending on the model 
as shown in the following illustration (IR2110B): 

 

Status Indicators 

The status indicators operate as follows: 

ON 

Illuminates steady red when power is applied. 

LAN 

On the IR2110B illuminates steady when there is a network 
connection to the LAN port and flashes when data is transmitted 
or received. 

ISDN: 
D, B1, B2 

Flash when data is transmitted/received over the ISDN D, B1 or 
B2 channels. 

DTE 0, 1 

Illuminate steady if a terminal is connected to the respective 
serial port and the DTR signal is on. Flashes when data is 
transmitted or received. DTE 1 is only present on the TA2020B. 

TA2020B & IR2110B Installation Guide 

Rear Panel Features 

The functions of these connectors are described in the following table: 

12V DC 

This jack socket is used to connect the unit to the power supply 
using 12V DC mains adapter. 

SERIAL 0 

This 25-way D socket provides a synchronous/asynchronous 
RS2322 serial port which may be used to connect the unit to a 
compatible serial device. The unit is supplied with a suitable 2 
metre serial cable. To comply with EMC requirements it should 
not be used with a longer cable. 

SERIAL 1 

On the TA2020B this 9-way D socket provides an asynchronous 
RS2322 serial port which may be used to connect the unit to a 
compatible serial device. The unit is supplied with a suitable 2 
metre serial cable. To comply with EMC requirements it should 
not be used with a longer cable. 

On the IR2110B, this port is disabled. 

LAN 

On the IR2110B this socket is used to connect the unit to a 
10/100-BaseT LAN using the 2-metre STP (Shielded Twisted 
Pair) cable supplied or a suitable alternative. This port is auto-
sensing for speed and wiring (straight-through or cross-over). To 
comply with EMC requirements it should not be used with non-
STP cable. 

ISDN 

This socket is used to connect the unit to an ISDN line. 

Reset switch 

This is located on the underside of the unit near the front. Pressing the switch gently with 
the tip of a pen or other suitable implement will generate a hardware reset. 

Содержание TA2020B

Страница 1: ...eliance on these materials Product disposal instructions The WEEE Waste Electrical and Electronic Equipment 2002 96 EC directive has been introduced to ensure that electrical electronic products are recycled using the best available recovery techniques to minimise the impact on the environment This product contains high quality materials and components which can be recycled At the end of it s life...

Страница 2: ... suitable for computers and other electronic equipment 6 Ports that are capable of connecting to other apparatus are defined as SELV ports To ensure conformity with EN60950 ensure that these ports are only connected to ports of the same type on other apparatus TA2020B IR2110B Installation Guide 3 Preface This guide describes the installation procedure for the TA2020B and IR2110B It is intended to ...

Страница 3: ...e described in the following table 12V DC This jack socket is used to connect the unit to the power supply using 12V DC mains adapter SERIAL 0 This 25 way D socket provides a synchronous asynchronous RS2322 serial port which may be used to connect the unit to a compatible serial device The unit is supplied with a suitable 2 metre serial cable To comply with EMC requirements it should not be used w...

Страница 4: ...he flashing stops the unit is ready to use TA2020B IR2110B Installation Guide 7 3 Configuration Once the TA2020B or IR2110B has be installed and powered up you must now configure the unit so that it can communicate with your network and the Internet 3 1 Configuring the TA2020B The TA2020B is configurable only through its serial port To access the web interface through the unit s serial port using ...

Страница 5: ...t to the appropriate COM port now using a suitable serial cable If you wish to configure a remote unit make sure it is connected to a suitable ISDN line and make a note of the ISDN number From the Windows Start menu select All Programs Accessories Communications New Connection Wizard You will be presented with the New Connection Wizard introduction screen Click on Next to proceed to the Network Co...

Страница 6: ... dialog Make sure that the Maximum speed bps value is set to 115200 and that the Enable hardware flow control box is checked TA2020B IR2110B Installation Guide 11 Click OK when you have finished to return to the main properties dialog Now select the Networking tab Make sure that the Type of dial up server I am calling is set to PPP Windows 95 98 NT 2000 Internet and click on Settings Make sure tha...

Страница 7: ...uide 13 3 2 Configuring the IR2110B The easiest way to configure the IR2110B is to use the Sarian Connection Wizard from the Sarian website The Sarian Connection Wizard will take you step by step through the process of configuring the router You can choose to just configure the unit s Ethernet port so that you can connect to it over your LAN in order to configure it fully or you can use the wizard...

Страница 8: ...tible via 9 way D socket TA2020B IR2110B Installation Guide 15 2 Declaration of Conformity Declaration of Conformity for R TTE Directive We Sarian Systems Limited Beacon House Riverside Business Park Ilkley West Yorkshire LS29 8JZ ENGLAND declare under our sole responsibility that the following product s Models TA2020B IR2110B Part numbers 81 TA2020B SSEU 00 81 IR2110B SSEU 00 conform s to the rel...

Отзывы: