background image

TA2020B & IR2110B Installation Guide 

12 

Step 4 – Initiating a DUN connection 

In the main dialog, you are asked to enter a username and password. The default settings 
for your unit are “username” and “password” respectively but you should change as soon 
as possible in order to prevent unauthorised access to your unit (refer to the section 
entitled Configure > Users in the Web Interface and Command Line Reference Guide for 
instructions on how to do this). The username is not case sensitive, but the password is. 

 

Note: 

When you type the password it will appear as a series of dots to ensure privacy. 

Once you have entered these, initiate a connection to your unit by clicking the 

Dial

 button. 

During the dialling and connection process, you may see a series of status dialogs and, if 
the connection is successful, the final dialog will indicate that the PPP login has been 
authenticated. 

After a short delay, this dialog will minimise to a “linked computers” icon in the Windows 
taskbar. 

You should now be ready to access the built-in web pages using your Web browser. The 
default “web address” for the unit is 

1.2.3.4

. By default, this is also mapped to the system 

IP hostname 

ss.2000r

You will need a valid username and password to access the web interface. Once again, 
the default settings are 

username

 and 

password

 respectively. If these values do not 

allow access, you should contact your system administrator. 

TA2020B & IR2110B Installation Guide 

13 

3.2  Configuring the IR2110B 

The easiest way to configure the IR2110B is to use the Sarian Connection Wizard, from 
the Sarian website. The Sarian Connection Wizard will take you step-by-step through the 
process of configuring the router. 

You can choose to just configure the unit’s Ethernet port (so that you can connect to it 
over your LAN in order to configure it fully), or you can use the wizard to configure the 
unit’s Ethernet port, and at the same time connect it to your wireless network. 

Using the wizard means that you will not have to change the IP address of your PC. 
Rather, you will be able to change the IP address of the router to match the subnet your 
PC is already on. 

Note: The default IP address for the LAN 0 port is 192.168.0.99, with a Class C subnet 
(255.255.255.0). Setting your PC’s IP address to one on the same subnet (192.168.0.*) 
will enable you to connect to the unit’s Web interface. You will then be able to configure 
the unit manually. 

Step 1 – Install the Connection Wizard 

Download the connection wizard from the Sarian website and install the software on your 
PC.  

Step 2 – Run the Wizard 

Once the wizard has been installed on your PC, start it by clicking 

Start

 

>

 

All Programs

 

>

 

Sarian Systems

 

>

 

Sarian Connection Wizard

 

>

 

Sarian Connection Wizard

Step 3 – Decide which configuration method to use 

Choose to configure the unit’s Ethernet port only. You must have completed all the 
installation steps listed in the previous section. 

Step 4 – Configure the unit 

Follow the on-screen instructions to configure the unit. Once complete you will be able to 
browse to the unit and configure it using your web browser. 

Содержание TA2020B

Страница 1: ...eliance on these materials Product disposal instructions The WEEE Waste Electrical and Electronic Equipment 2002 96 EC directive has been introduced to ensure that electrical electronic products are recycled using the best available recovery techniques to minimise the impact on the environment This product contains high quality materials and components which can be recycled At the end of it s life...

Страница 2: ... suitable for computers and other electronic equipment 6 Ports that are capable of connecting to other apparatus are defined as SELV ports To ensure conformity with EN60950 ensure that these ports are only connected to ports of the same type on other apparatus TA2020B IR2110B Installation Guide 3 Preface This guide describes the installation procedure for the TA2020B and IR2110B It is intended to ...

Страница 3: ...e described in the following table 12V DC This jack socket is used to connect the unit to the power supply using 12V DC mains adapter SERIAL 0 This 25 way D socket provides a synchronous asynchronous RS2322 serial port which may be used to connect the unit to a compatible serial device The unit is supplied with a suitable 2 metre serial cable To comply with EMC requirements it should not be used w...

Страница 4: ...he flashing stops the unit is ready to use TA2020B IR2110B Installation Guide 7 3 Configuration Once the TA2020B or IR2110B has be installed and powered up you must now configure the unit so that it can communicate with your network and the Internet 3 1 Configuring the TA2020B The TA2020B is configurable only through its serial port To access the web interface through the unit s serial port using ...

Страница 5: ...t to the appropriate COM port now using a suitable serial cable If you wish to configure a remote unit make sure it is connected to a suitable ISDN line and make a note of the ISDN number From the Windows Start menu select All Programs Accessories Communications New Connection Wizard You will be presented with the New Connection Wizard introduction screen Click on Next to proceed to the Network Co...

Страница 6: ... dialog Make sure that the Maximum speed bps value is set to 115200 and that the Enable hardware flow control box is checked TA2020B IR2110B Installation Guide 11 Click OK when you have finished to return to the main properties dialog Now select the Networking tab Make sure that the Type of dial up server I am calling is set to PPP Windows 95 98 NT 2000 Internet and click on Settings Make sure tha...

Страница 7: ...uide 13 3 2 Configuring the IR2110B The easiest way to configure the IR2110B is to use the Sarian Connection Wizard from the Sarian website The Sarian Connection Wizard will take you step by step through the process of configuring the router You can choose to just configure the unit s Ethernet port so that you can connect to it over your LAN in order to configure it fully or you can use the wizard...

Страница 8: ...tible via 9 way D socket TA2020B IR2110B Installation Guide 15 2 Declaration of Conformity Declaration of Conformity for R TTE Directive We Sarian Systems Limited Beacon House Riverside Business Park Ilkley West Yorkshire LS29 8JZ ENGLAND declare under our sole responsibility that the following product s Models TA2020B IR2110B Part numbers 81 TA2020B SSEU 00 81 IR2110B SSEU 00 conform s to the rel...

Отзывы: