IN
S
TALL COVER A
S
FOLLOW
S
:
FOR STANDARD AND PARALLEL ARM APPLICATION
•
S
crew
s
hort cover
s
crew (#
8
-
3
2 X 5/16) into top of c
as
e
a
pproxim
a
tely 2 t
u
rn
s
• A
ss
em
b
le pl
as
tic
su
pport
a
nd long cover
s
crew (#
8
-
3
2 X 1 1/4)
into
b
ottom of c
as
e
a
pproxim
a
tely 2 t
u
rn
s
• Hold
su
pport
a
g
a
in
s
t c
as
e (
a
pproxim
a
tely 2 t
u
rn
s
)
b
etween fl
a
nge
a
nd
s
crew he
a
d
• Po
s
ition cover on clo
s
er
a
nd tighten
s
crew
s
FOR TOP JAMB APPLICATION
• A
ss
em
b
le pl
as
tic
su
pport
a
nd long cover
s
crew (#
8
-
3
2 X 1 1/4")
into top of c
as
e
a
pproxim
a
tely 2 t
u
rn
s
•
S
crew
s
hort cover
s
crew (#
8
-
3
2 X 5/16") into
b
ottom of c
as
e
a
pproxim
a
tely 2 t
u
rn
s
•
S
lide cover into g
a
p
b
etween fl
a
nge
a
nd
s
crew he
a
d. Po
s
ition cover
on
clo
s
er
a
nd tighten
s
crew
s
GAP
S
HORT COVER
S
CREW
PLA
S
TIC
S
UPPORT AND
LONG COVER
S
CREW
IN
S
ERT I
S
REMOVABLE.
PLACE IN UNU
S
ED OPENING
S
HORT COVER
S
CREW
PLA
S
TIC
S
UPPORT AND
LONG COVER
S
CREW
IN
S
ERT I
S
REMOVABLE. PLACE IN UNU
S
ED OPENING
RIGHT HAND
ILLU
S
TRATED
8
PAG
E
FINAL ADJUSTMENT AND REGULATING PROCEDURE
FRAME
UNREINFORCED
DOOR
COVER
DOOR
S
TOP
MORTI
S
E
NUT HEAD
DRILL
3
/
8
" DIA.
HOLE FOR
MORTI
S
E
NUT BODY
DRILL 1/4" DIA.
HOLE FOR MOUNTING
S
CREW
S
1.
For top jamb and corner bracket
applications: The door closer foot
will be attached to the door in a
manner similar to that shown for
mounting the closer body.
2.
The appropriate mortise nuts
and screws will be suppled based
on door thickness.
Door construction must provide a
bridge type reinforcement to prevent
the door rail from collapsing when
through-bolts are tightened.
Adjustment hold open arm
Slight tightening or loosening of hold
open nut changes holding position of door.
Note: To protect wall, trim and closer, use a door stop
located 10
°
beyond hold open position but not beyond
the max. door opening shown on instructions.
HOLD
OPEN
NUT
U
S
E 15/16"
WRENCH TO
ADJU
S
T NUT
Minimum recommended door closing time is 6 Seconds for
doors opened to 90 degrees.
Use 1/8” hex (Allen) wrench to adjust valves as needed.
Closing and latching speeds:
Turn valves clockwise to slow down or counterclockwise to
speed up door movement.
Backcheck:
To regulate the intensity of back check action, turn valve clockwise
to increase or counterclockwise to decrease checking.
CAUTION: Set valve for slight cushioning effect; closer can be
damaged if the checking action is too abrupt. Never use
the backcheck as a door stop. Always use a door stop to stop
the door.
Delayed action feature (Optional feature on some models):
“Delayed action” provides slow door closing through the
delayed action range. Turn valve clockwise to slow down or
counterclockwise to speed up door movement.
DOOR WIDTH
1431 DOOR CLOSER
(INCHES)
24-30
TURN nut 1-3
30-36
FACTORY SET
36-42
TURN nut 1-4
42-48
TURN nut 7-9
NUMBER OF TURNS OF SPRING POWER ADJUSTING NUT
Adjusting door
to close due to
high draft
conditions may
exceed ADA
standards.
Consult local
ordinances
when fire doors
are involved
© SARGENT Manufacturing Company 2006, 2007 All rights reserved
FOR ASSISTANCE, CONTACT SARGENT AT 800-727-5477 or www.sargentlock.com
A7140E