User Manual & Datasheet V 2.3
7
Mechanical Specifications
Please refer to Table 3 for Mechanical Specifications.
PARAMETER
VALUE
Housing
•
SCUTE: Pressure die-cast aluminium weatherproof
(Rating IP-68)
•
FP2C: Cast aluminium, weatherproof & flameproof,
powder coated, suitable for Gas Groups IIA, IIB & IIC
as per IS-2148
Electrical Connector
PG-13.5, 1/2" BSP DC Glands, 1/2” NPT DC Glands
Mounting
•
Screwed - 1”/1 1/2” BSP/NTP(M)
•
Flanged - As per your specifications
•
Material - MS (Plated), SS
Sensing Fork
SS 316
Extension Pipe
GI (Galvanized Iron) / SS-304 / SS -316
Table 3: Mechanical Specifications
8
Installation & Handling Guidelines
The fork should be installed in horizontal or vertical position. The following image displays different allowable installation
positions. Observe that when installed directly under the material inlet source, a canopy called baffle of appropriate strength
and size should be welded right above the fork as shown.
While installing the instrument, please take care of the following points:
•
The instrument shouldn’t block the material filling inlet.
•
Secure the cover of housing tightly. Tighten the cable glands.
•
For side-mounting, provide a baffle to prevent the application material from falling on the fork.
Please refer to Figure 3.
Figure 3: Correct Side Mounting
•
When handling forks, do not lift them using their tines. Please see Figure 4.
•
The tines should not be bent and neither should their dimensions be altered. Deforming the shape of the tines may
interfere with the fork’s operating frequency. Please see Figure 4.
•
Make all electrical connections as instructed in the manual. Don’t power on the device before verifying the connections.
•
To prevent the ingress of moisture and water seepage in side mounting position, the cable entries should always point
downwards.