ALM/ZOOM (Alarm input setting)
1
Use the CURSOR button (
jldc
) to
select ALM or ZOOM for ALARM IN.
2
Use the CURSOR button (
jldc
) to
make the settings given below.
1
POLARITY
NO: Normal open (Normally open so closed
condition is detected as input.)
NC: Normal closed (Normally closed so
open condition is detected as input.)
2
MOTION (ALM setting)
OFF: Does not output a motion sensor
alarm.
OR: Outputs an alarm if either an external
alarm or a motion sensor alarm is
detected.
AND: Outputs an alarm when an external
alarm input and a motion sensor
alarm are detected at the same time.
3
ZOOM (ZOOM setting)
Set the zoom ratio for the following alarm
input reception.
Available settings: x1.4, x2, x2.8, x4, x6
4
DURATION
Set the duration for the following alarm input
reception.
Available settings: 5S (Seconds), 10S,
15S, 20S, 30S, 1M
(Minute), 2M, 3M, 4M,
5M
COLOR (Color or Black/White selection
setting)
The ALARM IN cord can be used to force the
image mode to color mode or black/white mode.
Use this setting when using this cord to force
the mode selection. However, when this setting
is being used, external alarm input cannot be
received.
Use the CURSOR button (
jldc
) and SET
button to make the settings given below.
1
First change DAY/NIGHT in the LENS
screen to COLOR. (See p20)
2
Select OPTION in the MAIN MENU and
display the OPTION screen.
3
Change ALARM IN in the ALARM
SETTING screen to COLOR.
ALARM SETTING
ALARM IN ALM
POLARITY NO
MOTION OFF
DURATION 5S
ALARM OUT OFF
POLARITY NO
ALARM SETTING
ALARM IN ZOOM
POLARITY NO
ZOOM x1.4
DURATION 5S
ALARM OUT OFF
POLARITY NO
DURATION
ALARM OUT
ALARM TIME
External alarm input
Motion sensor detection
LENS
FOCUS MANU ‚
ZOOM SET ‚
DAY/NIGHT COLOR‚
VIEW ANGLE OFF
ALARM SETTING
ALARM IN COLOR
POLARITY NO
MOTION OFF
ALARM OUT OFF
POLARITY NO
En
gl
is
h
40