CONNECTIONS
Connecting to other equipment
The connection cords can be identified by color in accordance with the device they are to be
connected to (see the color display label). Connect whichever cords are required.
Note: If part of the copper section of a wire is exposed after a cord has been connected, trim the end
of the wire so that no copper section is exposed in order to prevent short-circuits.
A
Using a camera control unit to select
menus
•
BLACK (VIDEO) cord:
If using menus, connect a VAC-60/70
camera control unit (sold separately).
The menus will be displayed on the monitor,
so that menu settings can be carried out
using the camera control unit without
needing to remove the camera cover from
the camera. Refer to the Instruction Manual
for the VAC-60/70 for further details.
Normally this cord should be connected to a
monitor or digital video recorder (or time
lapse VCR). (See p7)
B
Adjusting the zoom and focus
If a lens controller (applicable voltage:
±
6 –
±
12 V DC) or similar device is connected, it can
be used to carry out zoom and focus
adjustment. Refer to the Instruction Manual for
the lens controller for further details.
•
ORANGE (ZOOM) cord:
This cord is used to input zoom signals to
the camera. It is used to make wide
angle/telescoping adjustments.
•
YELLOW (FOCUS) cord:
This cord is used to input focus signals to the
camera. It is used to make far/near
adjustments.
*
The BROWN (GND) cord can be connected
to
_B_
,
_C_
or
_D_
.
ORANGE (ZOOM) cord
ZOOM signal
FOCUS signal
Ground
YELLOW (FOCUS) cord
BROWN (GND) cord *
Camera control unit
Eng
lis
h
9