6
English
Left
tubing
Right tubing
Right-rear tubing
(recommended)
Left-rear
tubing
Fig. 12
ø65 mm
Outdoor
Indoor
Slight
downward
slant to
outdoor side
Sealing putty
or stuffing
PVC pipe
Fig. 13
3. Install Indoor Unit
3-1. Install the Rear Panel
(1) Install the rear panel horizontally using a car-
penter’s level or inclinometer. Since the unit
was designed for water drainage to either the
left or right direction, depending on the outlet
side you require provide a slight downward gra-
dient to ensure adequate drainage of the water
pan in the correct direction. (Fig. 11)
(2) Fix the rear panel to the wall using screws
required for the wall type. Use plaster board fas-
teners / toggle bolts for hollow walls.
(3) Be sure to affix the rear panel securely enough to
hold the weight on an adult (at least 60 kg), with
attachment screws spaced to evenly divide the
weight of the unit.
3-2. Install the Tubing Hole
(1) Determine which side of the unit you should make
the hole for tubing and wiring. (Fig. 12)
(2) Make the tubing hole (ø65 mm) in the wall at a
slight downward slant to the outdoor side. (Fig. 13)
Before making the hole, check carefully that no studs
or pipes are directly run behind the spot to be cut.
The above precautions are also applicable if tubing
goes through the wall in any other location.
(3) Insert a PVC pipe in the hole to prevent the con-
nection piping and wiring from being damaged
when passing through the hole.
3-3. Install the Drain Hose
(1) The drain hose must be angled at a downward
slant for smooth, unimpeded drainage.
(2) Supply adequate support for the hose, and do not
pull on it or permit bends or water traps to occur.
The outlet end must not be immersed in water or
otherwise blocked. (Fig. 14)
(3) When extending the drain hose inside a room,
cover it with adequate insulation to prevent conden-
sation and dripping. This is important to avoid
damage to walls, floors, or room furnishings.
NOTE
No pooled water
or other blockage
No water traps
Avoid bent hose
Fig. 14
CAUTION
Also avoid areas where
electrical wiring or conduits
are located.
Use tape measure
as shown.
Position the end of
a tape measure at
.
ø65 mm
ø65 mm
Recommended mounting plate
retention spots
(5 spots in all)
Place a carpenter's level on raised tab.
160
mm
160
mm
101
mm
120.5
mm
Right side
Left side
Wall
Wall
Space
to wall
150 mm
or more
Space
to wall
150 mm
or more
Drain hose position
(Rear tubing hole)
(Rear tubing hole)
Fig. 11
10-061 SAP-KRV9AEH EN 4/27/10 4:42 PM Page 6