Special Remarks
‘‘DRY’’ (
) Operation
How it works?
•
If the room temperature is higher than the setting temperature, the
air conditioner operates in the same way as during cooling
operation. When the room temperature approaches the setting
temperature, the air conditioner switches to DRY operation and the
indoor fans operate irregularly.
In addition, the outdoor unit continues operation at lowered
capacity, and repeats the cycle of operation and shutdown if the
room temperature drops further.
If the outdoor unit stops when the room temperature is less than
20 °C, the indoor fan also stops. If the room temperature is less than
15 °C, both the indoor fan and outdoor unit stop.
Clicking Sound
Clicking sound is
heard from the air
conditioner
•
In cooling operation, any plastic parts may expand or shrink due to a
sudden temperature change. In this event, a clicking sound may
occur. This is normal, and the sound will soon disappear.
Remote control unit
•
The remote control unit sends the setting condition to the air
conditioner regularly at five minute intervals.
18
OI-306-18EG
oi306000