6
Indoor unit
SAP-KMV91G
´
3
Outdoor unit
SAP-CMV2441G
No. of Indoor Units
3-unit type
Power Source
220 – 230V ~ 50Hz
Cooling
Capacity
kW
6.45 (1.5 – 6.9)
BTU/h
22,000 (5,100 – 23,500)
Air circulation (High)
m
3
/ h
1,290
Moisture removal (High)
Liters/ h
3.9
Voltage rating
V
230
Available voltage range
V
198 – 253
Running amperes
A
11.7 (2.3 – 15.2)
Power input
W
2,430 (430 – 3,190)
Power factor
%
90
C.O.P.
W/W
2.7
Compressor locked rotor amperes
A
—
Performance
Electrical Rating
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Cooling: Indoor air temperature
27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Indoor unit
SAP-KMV91G
´
2 + KMV181G
Outdoor unit
SAP-CMV2441G
No. of Indoor Units
3-unit type
Power Source
220 – 230V ~ 50Hz
Cooling
Capacity
kW
6.9 (2.3 – 7.5)
BTU/h
23,500 (7,800 – 25,600)
Air circulation (High)
m
3
/ h
1,640
Moisture removal (High)
Liters/ h
5.3
Voltage rating
V
230
Available voltage range
V
198 – 253
Running amperes
A
11.6 (3.4 – 15.8)
Power input
W
2,400 (620 – 3,310)
Power factor
%
90
C.O.P.
W/W
2.9
Compressor locked rotor amperes
A
—
Performance
Electrical Rating
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Cooling: Indoor air temperature
27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.