16
English
When connecting each power wire to the corresponding terminal, fol-
low the instructions “How to connect wiring to the terminal” and fasten
the wire securely tight with the fixing screw of the terminal plate.
How to connect wiring to the terminal
a) For Indoor Unit
(1) Cut the wire end with a cutting pliers, then strip the insulation to
expose the wire about 7 mm. See the label (Fig. 26) near the ter-
minal plate.
(2) Using a screwdriver, loosen the terminal screw on the terminal
plate.
(3) Insert the wire and tighten the terminal screw completely using a
screwdriver.
b) For Outdoor Unit
I
For solid core wiring (or F-cable)
(1) Cut the wire end with a cutting pliers, then strip the insulation to
expose the solid wire about 25 mm. (Fig. 27)
(2) Using a screwdriver, remove the terminal screw(s) on the terminal
plate.
(3) Using the pliers, bend the solid wire to form a loop suitable for the
terminal screw.
(4) Shape the loop wire properly, place it on the terminal plate and fix
it securely with the removed terminal screw using a screwdriver.
I
For stranded wiring
(1) Cut the wire end with a cutting pliers, then strip the insulation to
expose the stranded wiring about
10 mm and tightly twist the wire ends.
(Figs. 28 and 29)
(2) Using a screwdriver, remove the terminal screw(s) on the terminal
plate.
(3) Using a ring connector fastener or pliers, securely clamp each
stripped wire end with a ring connector. (Fig. 28)
(4) Place the ring connector wire, and replace and tighten the
removed terminal screw using a screwdriver. (Fig. 30)
Solid wire
Loop
Insulation
25 mm
Fig. 27
STRIP
SIZE
7 mm (ACTUAL
SIZE)
Fig. 26
Stranded wire
Ring
connector
10 mm
Fig. 28
Screw
Ring connector
Terminal plate
Wire
Special
washer
Fig. 30
Screw and
special washer
Ring
connector
Wire
WARNING
Loose wiring may cause the terminal to
overheat or result in unit malfunction. A
fire hazard may also exist. Therefore, be
sure all wiring is tightly connected.
Twist wire ends
Fig. 29
5-4. How to Connect Wiring to the Terminal
1
2
3
4
2
3
1
E
D
C
B
A
Grounding line
L
N
OUTDOOR UNIT
(C)
(B)
Grounding line
(B)
1
2
3
4
2
3
1
(C)
(B)
Grounding line
(B)
1
2
3
4
2
3
1
2
3
1
2
3
1
1
2
3
4
1
2
3
4
(C)
(B)
Grounding line
(B)
(B)
(C)
(B)
Grounding line
(B)
(C)
(B)
(A)
T
erminal
INDOOR UNIT
T
erminal
INDOOR UNIT
T
e
rminal
INDOOR UNIT
T
e
rminal
INDOOR UNIT
T
e
rminal
T
e
rminal
(
2P
)
T
e
rminal
INDOOR UNIT
UNIT
B
UNIT
A
UNIT
C
UNIT
D
UNIT
E
L Power
Supply
N Single-phase 220-240V
AC
50Hz
Grounding line
220V
AC 60Hz
5-3. Wiring System Diagram (Fig. 25)
Fig. 25