5
English
G
install the indoor unit more than 1 meter away from any antenna or power lines or connecting wires used for television,
radio, telephone, security system, or intercom. Electrical noise from any of these sources may affect operation.
G
install in a sturdy manner to avoid increased operating noise.
Table 3
* If total tubing length becomes 45 to 80 m (max.), charge additional refrigerant (R410A) by 20 g/m.
No additional charge of compressor oil is necessary.
2-2. Connecting Indoor Units
Fig. 4b
Union
Flare
C
B
A
(SAP-KMRV74EH, KMRV94EH, KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
(SAP-KMRV74EH, KMRV94EH, KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
D
E
Outdoor unit
Indoor unit
(SAP-KMRV74EH, KMRV94EH, KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
(SAP-KMRV74EH, KMRV94EH, KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
(SAP-KRV184EH)
(SAP-KRV186EH)
9.52
6.35
9.52
6.35
12.70
6.35
9.52
6.35
9.52
6.35
9.52
12.70
12.70
9.52
9.52
9.52
12.70
( 12.70 9.52) Supplied reducer
Union
Flare
C
B
A
(SAP-KMRV74EH, KMRV94EH, KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
(SAP-KMRV74EH, KMRV94EH, KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
D
E
Outdoor unit
Indoor unit
(SAP-KMRV74EH, KMRV94EH,KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
(SAP-KMRV74EH, KMRV94EH,KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
(SAP-KMRV74EH, KMRV94EH, KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
9.52
12.70
12.70
9.52
9.52
9.52
6.35
9.52
6.35
9.52
6.35
9.52
6.35
9.52
6.35
9.52
12.70
( 12.70 9.52) Supplied reducer
(A)
(B)
Max. Allowable
Max. Allowable Total
Limit of
Limit of Elevation
Required Amount
Tubing Length
Tubing Length
Total Tubing Length
Difference of
Additional
Model
per unit
at shipment
(L1+L2+L3+L4+L5)
(H1, H2, H3, H4, H5)
Refrigerant
(m)
(L1+L2+L3+L4+L5)
(m)
(m)
(g/m)
*
(m)
CMRV3656
30
45 (L1+L2+L3+L4+L5)
80 (L1+L2+L3+L4+L5)
15
20
Fig. 4a
unit: mm
Figures (A) – (H) show the different types of indoor unit connections, including the use of a reducer.
To select the required indoor unit to be connected, refer to the Combination Table that was included in the
outdoor unit package.