Contents
Page
IMPORTANT!
Please Read Before Starting
..................................
2
1.
GENERAL
..........................................................
3
1-1. Tools Required for Installation (not supplied)
1-2. Accessories Supplied with Unit
1-3. Optional Copper Tubing Kit
1-4. Type of Copper Tube and Insulation Material
1-5. Additional Materials Required for Installation
2.
INSTALLATION SITE SELECTION
...................
4
2-1. Indoor Unit
2-2. Connecting Indoor Units
2-3. Outdoor Unit
2-4. Outer Dimensions of Outdoor Unit
2-5. Diagram of Outdoor Unit Installation
3.
INSTALLATION PROCESS
..............................
10
3-1. Embedding the Tubing and Wiring
3-2. Drain Cap and Drain Elbow
3-3. Use of the Flaring Method
3-4. Flaring Procedure with a Flare Tool
3-5. Caution Before Connecting Tubes Tightly
3-6. Tubing Connections
3-7. Insulation of Refrigerant Tubing
3-8. Taping the Tubes
3-9. Finishing the Installation
4.
AIR PURGING
...................................................
12
I
Air Purging with a Vacuum Pump (for Test Run)
I
Pump Down
5.
WIRING INSTRUCTIONS
.................................
15
5-1. General Precautions on Wiring
5-2. Recommended Wire Length and Diameter
5-3. Wiring System Diagram
5-4. How to Connect Wiring to the Terminal
5-5. Wiring Instructions for the Outdoor Unit
6.
TEST RUN
.........................................................
18
7.
CONNECTING A HOME AUTOMATION
DEVICE
.............................................................
19
8.
INSTALLATION CHECK SHEET
......................
19
9.
ELECTRIC WIRING DIAGRAM
........................
19
INSTALLATION INSTRUCTIONS
Model Combinations
Combine indoor and outdoor units only as listed below.
Indoor Unit
Outdoor Unit
Power Source:
50 Hz, single-phase, 220 – 240 VAC
Be sure to connect indoor and outdoor units
only in combinations that are listed in the
combination table(s) included in the outdoor
unit package.
Connecting any other model may result in
operation failure and malfunction.
CAUTION
– Inverter Multi Split System Air Conditioner –
COOL / DRY/ HEAT Model
This air conditioner uses the new refrigerant R410A.
Be sure to read the yellow instruction sheet
attached to the outdoor unit for models using the
new refrigerant R410A.
The illustrations are based on the typical appearance of
a standard model. Consequently, the shape may differ
from that of the air conditioner that you are installing.
NOTE
Indoor unit C
Indoor unit D
Outdoor unit
Indoor unit B
Indoor unit A
Indoor unit E
Combination example
For Outdoor Unit
85264190
480
001 © SANYO 2009
SANYO Electric Co., Ltd.
Osaka, Japan
Español
Français
Deutsch
Italiano
Português
EE
ÏÏ
ÏÏ
ËË
ÓÓ
ÈÈÎÎ
¿¿
English
SAP-KMRV74EH
SAP-KMRV94EH
SAP-KMRV124EH
SAP-KMRV76EH
SAP-KMRV96EH
SAP-KMRV126EH
SAP-KRV96EHDS
SAP-KRV126EHDS
SAP-KRV184EH
SAP-KRV244EH
SAP-KRV186EH
SAP-KRV246EH
SAP-CMRV3656EH
08-342 CMRV3656EH_OU EN 6/9/09 2:27 PM Page a