15
■
2 - indoor units in operation A + B
COOLING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.30
0.42
8.38
9.1
Power Input
kW
0.070
0.092
1.958
2.12
Full Load Conditions Running Amps.
A
0.30
0.42
11.28
12.0
Power Input
kW
0.070
0.092
2.588
2.75
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
HEATING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.30
0.42
8.18
8.9
Power Input
kW
0.070
0.092
1.838
2.00
Full Load Conditions Running Amps.
A
0.30
0.42
10.88
11.6
Power Input
kW
0.070
0.092
2.438
2.60
Rating Conditions
: Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full Load Conditions : Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°C D.B. / 18°C W.B.
Indoor Unit
SAP – K97AHA (
✕
2)
Outdoor Unit
SAP – CM1827AHA
NOTE
A : SAP–K97AHA
B : SAP–K97AHA