13
Insulation of Refrigerant Tubing
Because capillary tubing is used in the outdoor unit, both the
wide and narrow tubes of this air conditioner become cold. To
prevent heat loss and wet floors due to dripping of condensa-
tion, both tubes must be well insulated with a proper insulation
material. The thickness of the insulation should be a min. 8
mm.
After a tube has been insulated,
never try to bend it into a narrow
curve because it can cause the tube
to break or crack.
IMPORTANT
Wide tube
Thickness:
Min. 8 mm
Insulation
Narrow tube
Thickness:
Min. 8 mm
CAUTION
H
e
a
t
e
x
c
h
a
n
g
e
r
Narrow tube
O.D.
6.35mm
(1/4")
Wide tube
O.D.
9.52mm
(3/8")
Muffler
Accumulator
Compressor A
Capillary
tube
( )
Check valve
Strainer
H
e
a
t
e
x
c
h
a
n
g
e
r
Narrow tube
O.D.
6.35mm
(1/4")
Wide tube
O.D.
9.52mm
(3/8")
Muffler
Accumulator
Compressor B
( )
Check valve
Strainer
H
e
a
t
e
x
c
h
a
n
g
e
r
Check
port
Check
port
Indoor Unit A
Indoor Unit B
Wide Tube Service valve
Narrow Tube Service valve
Capillary tube
Drier
Drier
4 – Way
valve
4 – Way
valve