2. SPECIFICATIONS
2-1. Unit Specifications
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Cooling: Indoor air temperature 27°C DB/19°C WB
Outdoor air temperature 35°C DB/24°C WB
Heating: Indoor air temperature 20°C DB
Outdoor air temperature 7°C DB/6°C WB
2
No. of indoor units.
1-unit
2-unit
Power Source
240 V 1-phase 50 Hz
240 V 1-phase 50 Hz
Cooling
Heating
Cooling
Heating
Capacity
kW
2.65
3.30
5.10
6.35
BTU/h
9,000
11,300
17,400
21,700
Air circulation (High)
m
3
/h
450
450 x 2
Moisture removal (High)
Liters/h
1.1
—
1.1 x 2
—
Voltage rating
V
240
240
Available voltage range
V
216 to 264
216 to 264
Running amperes
A
4.6
4.9
9.1
8.9
Power input
W
1,040
1,090
2,120
2,000
Power factor
%
94
93
97
94
C.O.P.
W/W
2.5
3.0
2.4
3.2
Compressor locked rotor amperes
A
25
50
Controls / Temperature control
Microprocessor / I.C. thermostat
Control unit
Wireless remote control unit
Timer
1-hour OFF / 12-hour ON or OFF
Fan speeds
Indoor / Outdoor
3 and Auto / 1
Airflow direction (Indoor)
Horizontal
Manual
Vertical
Auto
Air filter
Washable, Anti–Mold
Compressor
Rotary (Hermetic)
Refrigerant / Amount charged at shipment
g
R22 / 1,200
Refrigerant control
Capillary tube
Operation sound
Indoor – Hi / Me / Lo
dB-A
40 / 34 / 31
Outdoor – Hi
dB-A
53
Refrigerant tubing connections
Flare type
Max. allowable tubing length at shipment
m
7.5
Refrigerant tube
Narrow tube
mm (in.)
6.35 (1/4)
diameter
Wide tube
mm (in.)
9.52 (3/8)
Refrigerant tube kit / Accessories
Optional / Hanging wall bracket
Indoor Unit
Outdoor Unit
Unit dimensions
Height
mm
265
630
Width
mm
805
830
Depth
mm
145
305
package dimensions
Height
mm
208
713
Width
mm
855
994
Depth
mm
326
413
Weight
Net
kg
7.5
61.0
Shipping
kg
10.0
66.0
Shipping volume
m
3
0.06
0.29
Dimensions & Weight
Features
Electrical Rating
Performance
Indoor Unit
SAP – KM97AHA
Outdoor Unit
SAP – CM1827AHA
Содержание SAP-CM1821AHA
Страница 49: ......