7. ELECTRICAL DATA
7-1. Electrical Characteristics
■
1 - indoor unit in operation
■
2 - indoor units in operation
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.36
0.50
8.44
9.3
Power Input
kW
0.080
0.119
1.921
2.12
Full Load Conditions Running Amps.
A
0.36
0.50
10.04
10.9
Power Input
kW
0.080
0.119
2.261
2.46
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit
SAP – K91A (
✕
2)
Outdoor Unit
SAP – CM1821A
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.18
0.50
4.32
5.0
Power Input
kW
0.040
0.119
0.951
1.11
Full Load Conditions Running Amps.
A
0.18
0.50
5.12
5.8
Power Input
kW
0.040
0.119
1.121
1.28
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit
SAP – K91A (
✕
1)
Outdoor Unit
SAP – CM1821A
12