Operation with the Remote Control Unit (continued)
•
This appliance has a built-in 3-minute time delay circuit to ensure reliable
operation. When the operation button is pressed, the compressor will start
running within three minutes. In the event of power failure, the unit will
stop. When the power is restored, the unit will restart automatically after
three minutes.
2. Adjusting the
Fan Speed
A. Automatic
Simply set the FAN SPEED selector button to the
position.
A microcomputer in the air conditioner automatically controls the fan speed
when the
mode is selected. When the air conditioner starts operating,
the difference between the room temperature and the set temperature is
detected by the microcomputer which then automatically switches the fan
speed to the most suitable level.
Cooling and DRY mode:
B. Manual
If you want to adjust fan speed manually during operation, just set the FAN
SPEED selector button as desired. [
,
, or
]
NOTE
When difference between
room temperature and set
FAN SPEED
temperature is
2°C and over
High
Between 2°C and 1°C
Medium
Below 1°C
Low
SAP-K161~241GJA 3/4/00 16:36pm Page 13