35
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
220V ~ 60Hz
Rating Conditions
Running Amps.
A
0.42
0.60
13.48
14.5
Power Input
kW
0.086
0.131
2.673
2.89
SSA 385, 386
Running Amps.
0.42
0.60
15.78
16.8
Conditions
Power Input
0.086
0.131
3.173
3.39
Full Load Conditions Running Amps.
A
0.42
0.60
18.98
20.0
Power Input
kW
0.086
0.131
3.863
4.08
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
SSA 385, 386 Conditions (Saudi standard)
: Indoor Air Temperature 29°C D.B. / 19°C W.B.
Outdoor Air Temperature 46°C D.B. / 24°C W.B.
Full Load Conditions : Indoor Air Temperature 29°C D.B. / 19°C W.B.
Outdoor Air Temperature 54°C D.B.
Indoor Unit
SAP – K241GJA
SAP – K241MBA
Outdoor Unit
SAP – C241JA
SAP – C241BA
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
220 – 240V ~ 50Hz
Rating Conditions
Running Amps.
A
0.39
/
0.40
0.49
/
0.50
11.92 / 11.90
12.8
/
12.8
Power Input
kW 0.075 / 0.080
0.106 / 0.118
2.469 / 2.562
2.65
/
2.76
Full Load Conditions Running Amps.
A
0.39
/
0.40
0.49
/
0.50
16.62 / 15.90
17.5
/
16.8
Power Input
kW 0.075 / 0.080
0.106 / 0.118
3.509 / 3.542
3.69
/
3.74
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 52°C D.B.
Indoor Unit
SAP – K241GJA
SAP – K241MBA
Outdoor Unit
SAP – C241GA
SAP – C241MA