- 65 -
No.
Adjustment Item
Initial Value
Range
Input source / Description
Group:250 FAN CONTROL
0
Fan Control Mode 1
0
0 - 2
0 : Normal, 1: Ceiling, 2 : Highland
1
Fan Control Mode 2
0
0 - 1
0 : Normal, 1 : Forced Highland Mode
2
Fan SW
0
0 - 3
0 : Auto, 1 : Temp. min, 2 : Tepm. max, 3 : Manual
3
Manual Fan1 Voltage
130
0 - 145
Fan operating voltage at he Manual
4
Manual Fan2 Voltage
130
0 - 145
5
Manual Fan3 Voltage
130
0 - 145
6
Manual Fan4 Voltage
130
0 - 145
7
Manual Fan5 Duty
500
1 - 510
Fan5 Duty value at the Manual
8
Fan1 Min Adjust
✻
22
0 - 255
Fan minimum voltage (3.5V) adjustment
9
Fan2 Min Adjust
✻
22
0 - 255
10
Fan3 Min Adjust
✻
22
0 - 255
11
Fan4 Min Adjust
✻
22
0 - 255
12
Fan1 Max Adjust
✻
232
0 - 255
Fan max voltage (13.8V) adjustment
13
Fan2 Max Adjust
✻
232
0 - 255
14
Fan3 Max Adjust
✻
232
0 - 255
15
Fan4 Max Adjust
✻
232
0 - 255
16
Fan1 Min Limit
43
30 - 145
Min voltage that Fan works
17
Fan2 Min Limit
30
30 - 145
18
Fan3 Min Limit
40
30 - 145
19
Fan4 Min Limit
30
30 - 145
20
Fan5 Min Limit
67
1 - 510
Min duty ratio that Fan5 works
21
Fan1 Max Limit
138
30 - 145
Max voltage that Fan works
22
Fan2 Max Limit
138
30 - 145
23
Fan3 Max Limit
138
30 - 145
24
Fan4 Max Limit
138
30 - 145
25
Fan5 Max Limit
510
1 - 510
Max duty ratio that Fan5 works
26
Fan1 Min Rpm
105
0 - 4500
Fan1 min revolution
27
Fan2 Min Rpm
510
0 - 6510
Fan2 min revolution
28
Fan3 Min Rpm
105
0 - 4500
Fan3 min revolution
29
Fan4 Min Rpm
510
0 - 6510
Fan4 min revolution
30
Fan5 Min Rpm
300
0 - 6510
Fan5 min revolution
31
Fan1 Max Rpm
4500
510 - 4500
Fan1 maximam revolution
32
Fan2 Max Rpm
6510
510 - 6510
Fan2 maximam revolution
33
Fan3 Max Rpm
4500
510 - 4500
Fan3 maximam revolution
34
Fan4 Max Rpm
6510
510 - 6510
Fan4 maximam revolution
35
Fan5 Max Rpm
6510
510 - 6510
Fan5 maximam revolution
Norm/Celing/Highland/Focus
36
Normal Fan1 Min
1380/1380/1545/1545
510 - 4500
Normal_Temp.-Min Fan revolution
37
Normal Fan2 Min
2220/2220/3420/-
510 - 6510
38
Normal Fan3 Min
1905/1905/2100/2100
510 - 4500
39
Normal Fan4 Min
2595/2595/4050/5115
510 - 6510
40
Normal Fan5 Min
1905/1905/2745/3165
510 - 6510
41
Normal Fan1 Max
1470/1470/1710/1710
510 - 4500
Normal_Temp.-Max Fan revolution
42
Normal Fan2 Max
2460/2460/3630/-
510 - 6510
43
Normal Fan3 Max
1905/1905/2100/2100
510 - 4500
44
Normal Fan4 Max
5115/5115/5515/5115
510 - 6510
45
Normal Fan5 Max
3240/3240/3240/3240
510 - 6510
46
Normal TempA Low
28/28/27/-
-5 - 100
Normal_Temp. -sensor A_Control_Start-temp.
47
Normal TempA High
36/36/35/-
-5 - 100
Normal_Temp. -sensor A_Control_End-temp.
48
Normal TempB Low
49/49/52/-
-5 - 100
Normal_Temp. -sensor B_Control_Start-temp.
49
Normal TempB High
54/54/57/-
-5 - 100
Normal_Temp. -sensor B_Control_End-temp.
50
Normal TempC Low
49/49/47/-
-5 - 100
Normal_Temp. -sensor C_Control_Start-temp.
51
Normal TempC High
54/54/51/-
-5 - 100
Normal_Temp. -sensor C_Control_End-temp.
Electrical Adjustments
Содержание PLV-Z3000
Страница 113: ...ME4 Z300000 113 113 M01 M05 M07 M12 M14 M15 M16 M17 M18 M24 M24 M27 M25 Cabinet Front ass y Mechanical Parts List ...
Страница 114: ... 114 ME4 Z300000 114 M22 M26 M31 M32 M34 M46 Optical Parts Location Optical Unit Mechanical Parts List L02 L04 M49 M48 ...
Страница 120: ... ME4A Dec 2008 DC 200 Printed in Japan SANYO Electric Co Ltd ...