- 45 -
■
Optical Adjustment
Before taking optical adjustments below, remove the Cabinet Top following to the "Mechanical Disassemblies".
Adjustments require a 2.0mm hex wrench, Philips Screwdriver and a slot screwdriver. When you adjust Integrator lens or Relay
lens adjustment, you need to disconnect some connectors and FPC cables of LCD panels on the main board.
Note:
Do not disconnect connectors on the main board, because the projector can not turn on or operate properly for
adjustment.
(1) Contrast adjustment
Polarized glass (G)
Optical filter (G)
WARNING : USE UV RADIATION EyE AND SKIN PROTECTION
DURING SERVICING
CAUTION: To prevent suffer of UV radiation, those adjustments
must be completed within 25 minutes.
(1) Contrast adjustment
Polarized glass (R)
Optical filter (R)
(1) Contrast adjustment
Polarized glass (B)
Optical filter (B)
Fixed (LENS RELAY_OUT)
Do not adjust
Fixed (LENS CONDENSOR_OUT)
Do not adjust
Содержание PLV-Z3000
Страница 113: ...ME4 Z300000 113 113 M01 M05 M07 M12 M14 M15 M16 M17 M18 M24 M24 M27 M25 Cabinet Front ass y Mechanical Parts List ...
Страница 114: ... 114 ME4 Z300000 114 M22 M26 M31 M32 M34 M46 Optical Parts Location Optical Unit Mechanical Parts List L02 L04 M49 M48 ...
Страница 120: ... ME4A Dec 2008 DC 200 Printed in Japan SANYO Electric Co Ltd ...