PLV-HD2000 Expand Serial Command Functional Specifications
56/56
10.3. Status Read Command with Address
10.3.1.
Format
1) PC issues a command in format as below:
“A” Address “CR” Command [CR]
or
“A” Address “CR_” Command [CR]
Address: 3-digit number (“001” – “999”)
Command: string (Refer to Basic and Expand Serial Command)
2) The only projector with appropriate address decodes the received commands and
returns the character line as the required data.
Required Data [CR]
Required Data: string (Refer to Basic Status Read Command)
3) When the received data cannot be decoded, it returns
“ ? “ [CR]