PLV-HD2000 Expand Serial Command Functional Specifications
49/56
9.9.5. CR_LANG Command
Command “CR_LANG”
[CR]
Details
Get currently selected language
Acceptable “000_%1”
[CR]
%1
“ENG” --------------------------- English is selected
“DEU” --------------------------- German is selected
“FRA” ---------------------------- French is selected
“ITA” ------------------------------ Italian is selected
“ESP” ---------------------------- Spanish is selected
“POR” ---------------------------- Portuguese is selected
“NED” ---------------------------- Dutch is selected
“SVE” ---------------------------- Swedish is selected
“CHI” ----------------------------- Chinese is selected
“KOR” ---------------------------- Korean is selected
“JPN” ---------------------------- Japanese is selected
“RUS” ---------------------------- Russian is selected
Response
Unacceptable “Error Code” [CR]
9.9.6. CR_ON-STA Command
Command “CR_ON-STA”
[CR]
Details
Get setting status of Power ON
Acceptable “000_%1”
[CR]
%1
“ON” ----------------- Power ON Start is set to ON.
“OFF” --------------- Power ON Start is set to OFF.
Response
Unacceptable “Error Code” [CR]
9.9.7. CR_P-MANE Command
Command “CR_P-MANE”
[CR]
Details
Get setting status of Power management
Acceptable “000_%1”
[CR]
%1
“OFF” ------------------------ Power management is set to OFF
“READY” -------------------- Power management is set to Ready
“SHUTDOWN” ------------ Power management is set to Shut Down
Response
Unacceptable “Error Code” [CR]
9.9.8. CR_P-MANETIME Command
Command “CR_P-MAETIME”
[CR]
Details
Get set time to start Power management
Acceptable “000_%1”
[CR]
%1
“001” – “030” --------------------- 1 to 30 minute(s)
Response
Unacceptable “Error Code” [CR]