-66-
Electrical Adjustment
Grp / No.
Item
Function
Range
Initial
Note
15
Filter 2nd Cartridge Scroll Factor 6
0 - 255
255
16
Filter 2nd Cartridge Scroll Factor 7
0 - 255
255
17
Filter 2nd Cartridge Scroll Factor 8
0 - 255
255
18
Filter 2nd Cartridge Scroll Factor 9
0 - 255
255
19
Filter 2nd Cartridge Scroll Factor 10
0 - 255
255
20
Filter 3rd Cartridge Scroll Factor 1
3rd Filter Cartridge Scrolling Factor at N times Scrolling (N:1-10)
0: Manual Scrolling with OSD Menu
1: Auto Scrolling detecting by Filter Clogged
2: Auto Scrolling detecting by specified maximum used time per
a sheet
0 - 255
255
21
Filter 3rd Cartridge Scroll Factor 2
0 - 255
255
22
Filter 3rd Cartridge Scroll Factor 3
0 - 255
255
23
Filter 3rd Cartridge Scroll Factor 4
0 - 255
255
24
Filter 3rd Cartridge Scroll Factor 5
0 - 255
255
25
Filter 3rd Cartridge Scroll Factor 6
0 - 255
255
26
Filter 3rd Cartridge Scroll Factor 7
0 - 255
255
27
Filter 3rd Cartridge Scroll Factor 8
0 - 255
255
28
Filter 3rd Cartridge Scroll Factor 9
0 - 255
255
29
Filter 3rd Cartridge Scroll Factor 10
0 - 255
255
250
Fan Voltage Adjustment
0
Fan 1 Min Adjust (DAC)
DAC Output for Fan Voltage adj.
Adjust Tolerance between DAC and Fan Volt.
*Lamp Mode: Eco
0-255
32
* Fan voltage adj.
1
Fan 1 Max Adjust (DAC)
0-255
240
* Fan voltage adj.
2
Fan 2 Min Adjust (DAC)
0-255
32
* Fan voltage adj.
3
Fan 2 Max Adjust (DAC)
0-255
240
* Fan voltage adj.
4
Fan 3 Min Adjust (DAC)
0-255
32
* Fan voltage adj.
5
Fan 3 Max Adjust (DAC)
0-255
240
* Fan voltage adj.
6
Fan 4 Min Adjust (DAC)
0-255
35
* Fan voltage adj.
7
Fan 4 Max Adjust (DAC)
0-255
230
* Fan voltage adj.
8
Fan 5 Min Adjust (DAC)
0-255
35
* Fan voltage adj.
9
Fan 5 Max Adjust (DAC)
0-255
230
* Fan voltage adj.
10
Fan 6 Adjust (DAC)
0-255
190
* Fan voltage adj.
11
Fan 7 Adjust (DAC)
0-255
190
* Fan voltage adj.
12
Fan 8 Adjust (DAC)
0-255
190
* Fan voltage adj.
252
Fan Option
1
Safety Switch
Safety Application use
0-6
0
2
Fan Manual Switch
Fan Manual SW (0: Auto 1: Manual)
0-1
0
3
Fan1 Manual Voltage
Manual Adjustment Mode (0.1V)
*Effective only when Manual SW is 1.
0-255
100
4
Fan2 Manual Voltage
0-255
100
5
Fan3 Manual Voltage
0-255
100
6
Fan4 Manual Voltage
0-255
100
7
Fan5 Manual Voltage
0-255
100
8
Fan6-8 Manual Voltage
0-255
100
9
All Fan Max Min Control
Forced mode of Lamp mode - Fan Control.
0: Normal, 1: High-MIN, 2: High-MAX, 3: Normal-MIN, 4:
Normal-MAX, 5: Eco1-MIN, 6: Eco1-MAX, 7: Eco2-MIN, 8: Eco2-
MAX
0 - 8
0
10
Press Data
Air Pressure Data (Read only)
-
-
L1
L3
Normal
Ceiling
L4
110°
-110°
70°
0°
180°
-70°
L2
Off
L1
L2
L3
L4
Off
Normal
Up
Down
Normal
Ceiling
On
Ceiling
Up
Down
Normal
Ceiling
Slant
Ceiling
Definition of Slant
Off
-70° ~ 70°
L1
70° ~ 110°
L2
-70° ~ -110°
L3
-70° ~ 70°
L4
110° ~ -110°
253
Fan Temp Error Setting
(Memorized)
Normal Ceiling
Top
Bottom
0
Temp A Warning (High)
Temp A (Room) to judge the Temp Error at High
30-100
51
51
51
51
1
Temp B Warning (High)
Temp B (Lamp) to judge the Temp Error at High
30-100
64
64
64
64
2
Temp C Warning (High)
Temp C (Panel) to judge the Temp Error at High
30-100
59
59
59
59
3
Temp B-A Warning (High)
Temp B - A (Filter Clogged) to judge the Temp Error at High
0-100
100
100
100
100
4
Temp C-A Warning (High)
Temp C - A (Filter Clogged) to judge the Temp Error at High
0-100
100
100
100
100
5
Temp A Warning (Normal)
Temp A (Room) to judge the Temp Error at Normal
30-100
51
51
51
51
6
Temp B Warning (Normal)
Temp B (Lamp) to judge the Temp Error at Normal
30-100
64
64
64
64
7
Temp C Warning (Normal)
Temp C (Panel) to judge the Temp Error at Normal
30-100
59
59
59
59
8
Temp B-A Warning (Normal)
Temp B - A (Filter Clogged) to judge the Temp Error at Normal
0-100
100
100
100
100
9
Temp C-A Warning (Normal)
Temp C - A (Filter Clogged) to judge the Temp Error at Normal
0-100
100
100
100
100
10
Temp A Warning (Eco)
Temp A (Room) to judge the Temp Error at Eco
30-100
51
51
51
51
11
Temp B Warning (Eco)
Temp B (Lamp) to judge the Temp Error at Eco
30-100
64
64
64
64
12
Temp C Warning (Eco)
Temp C (Panel) to judge the Temp Error at Eco
30-100
59
59
59
59
13
Temp B-A Warning (Eco)
Temp B - A (Filter Clogged) to judge the Temp Error at Eco
0-100
100
100
100
100
14
Temp C-A Warning (Eco)
Temp C - A (Filter Clogged) to judge the Temp Error at Eco
0-100
100
100
100
100
Содержание PLC-XTC50L
Страница 98: ... 98 IC Block Diagrams DS16EV5110 DVI Equalizer IC8001 FA7701 Switching Controller IC3611 IC7761 IC7701 IC7731 ...
Страница 99: ... 99 IC Block Diagrams ISL98001 A D Converter IC2201 L3E06170 S H IC501 IC531 IC561 ...
Страница 100: ... 100 IC Block Diagrams M62393 DAC IC7971 L3E07111 LCD DRIVE DIGITAL GAMMA IC401 ...
Страница 101: ... 101 IC Block Diagrams NJM2671 Motor Controller IC7601 PIC16LF819 PIC IC4501 ...
Страница 102: ... 102 IC Block Diagrams PW392 Scaler IC301 PW610 Keystone IC2301 ...
Страница 103: ... 103 IC Block Diagrams TE7783 I O Expander IC4801 TPA3123 Audio Output IC5051 ...
Страница 104: ... 104 IC Block Diagrams UPC324GR Ope Amp IC1423 ...
Страница 112: ... 112 Parts Location Diagrams KH7 XTC50L00 Condenser lens in assembly L08 Relay lens out assembly L12 M18 M18 ...
Страница 113: ... 113 Parts Location Diagrams KH7 XTC50L00 Mirror assembly L16 Integrator Lens assembly L07 L06 L07 ...
Страница 153: ...Key No Part No Description Key No Part No Description KH7 XTC50L00 153 Electrical Parts List ...