PDG-DWL2500 Expand Serial Command Functional Specifications
65/72
Details
Get setting status of Terminal
Acceptable
“000_%1”[CR]
%1
“COMPUTER”-------------Computer Input mode
“MONITOR”----------------Monitor Out mode
Response
Unacceptable “?”[CR]
9.11.15 CR_STANDBYMODE Command
Command “CR_STANDBYMODE” [CR]
Details
Get Standby Mode setting status
Acceptable
“000_%a”[CR]
%a
“ECO” -------------- Eco Mode
“NORMAL” -------- Network Mode
Response
Unacceptable “Error code”[CR]
9.11.16 CR_P-MANE Command
Command “CR_P-MANE”[CR]
Details
Get Power management setting status
Acceptable
“000_%a”[CR]
%a
“OFF” -------------------------- Power Management is OFF
“READY” ---------------------- Power Management is Ready
“SHUTDOWN” ---- Power Management is set to Shut Down mode
Response
Unacceptable “Error code”[CR]
9.11.17 CR_P-MANETIME Command
Command “CR_P-MANETIME”[CR]
Details
Get time to start Power Management
Acceptable
“000_%a”[CR]
%a
“001”~”030” -----------------------1 minute to 30 minutes
Response
Unacceptable “Error code”[CR]
9.11.18 CR_ON-STA Command
Command “CR_ON-STA”[CR]
Details
Get Direct on setting status
Acceptable
“000_%a”[CR]
%a
“ON” ------------------------- Direct on is active
“OFF” ------------------------ Direct on is inactive
Response
Unacceptable “Error code”[CR]