8.10.26 CF_FANMODE Command
Command “CF_FANMODE_%1”[CR]
%1
“L1” ---------------------------- Set Fan Mode to L1
“L2” ---------------------------- Set Fan Mode to L2
Details
Switch Fan Mode
When L1 is selected, fan noise after POWER OFF is louder.
When L2 is selected, fan noise after POWER OFF becomes quiet.
However fan rotates longer than L1.
The status set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.10.27 CF_FANCONTROL Command
Command “CF_FANCONTROL_%1”[CR]
%1
“OFF” ---------------------------- Set Fan control to Off
“ON1” ---------------------------- Set Fan control to On1
“ON2” ---------------------------- Set Fan control to On2
Details
Set Fan control setting.
The status set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.10.28 CF_FILTIMER Command
Command “CF_FILTIMER_%1”[CR]
%1
“2000” -------------------- Set 2000 hours
“3000” -------------------- Set 3000 hours
“4000” -------------------- Set 4000 hours
“OFF” --------------------- No warning display
“UP” --------------------- The same operation as pressing Up key or Left key
“DN” ---------------------The same operation as pressing Down key or Right key
Details
Set timer of Filter warning display.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.10.29 CF_FILH Command
Command “CF_FILH_%1”[CR]
%1
“RST” ---------------Reset Filter used time
Details
Reset filter used time
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]