PDG-DWL2500 Expand Serial Command Functional Specifications
40/72
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.10.19 CF_P-MANETIME Command
Command “CF_P-MANETIME_%1”[CR]
%1
“01” ~ ”30” ----------------------- Directly select setting time by the minute
“UP” ------------------------------- Plus one minute (01
→
02
→
・・・
→
30
→
01)
“DN” ------------------------------- Minus one minute(30
→
29
→
・・・
→
01
→
30)
Details
Set Power Management time
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.10.20 CF_ON-STA Command
Command “CF_ON
−
STA_%1”[CR]
%1
“ON” --------------------------- Set Direct on active
“OFF” ------------------------- Set Direct on inactive
“UP” --------------------------- Switch setting (On
→
Off
→
On
→
・・・
)
“DN” --------------------------- Switch setting (On
→
Off
→
On
→
・・・
)
Note) “UP” and “DN” behave the same.
Details
Set/Cancel Power ON Start
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.10.21 CF_CCAPTIONDISP Command
Command “CF_CCAPTIONDISP_%1”[CR]
%1
“OFF” ------------- Select Off
“CC1” ------------- Select CC1
“CC2” ------------- Select CC2
“CC3” ------------- Select CC3
“CC4” ------------- Select CC4
Details
Select channel of Closed caption.
The status set with this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Note)Closed caption is available under conditions below;
Entered signal is appropriate (Video, NTSC signal of S-video).
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.10.22
CF_CCAPTIONCOLOR Command
Command “CF_CCAPTIONCOLOR_%1”[CR]
%1
“COLOR” ------- Select Color