SETUP FOR RS-232C OR RS-485 USE
The VCR can be controlled by a computer connected to
the RS-232C connector. It can also be controlled through
a special controller connected to the RS-485 connector.
You must specify which connector (RS-232C or RS-485)
is used. (Refer to “DIP Switches Setup”)
DIP Switches Setup
The DIP switches need to be set when a computer,
special controller, etc. connected to the RS-232C or
RS-485 connectors is used to control the VCR. Make sure
to turn the VCR power off before setting the DIP switches.
SW No.
1-7: To setup the VCR address (only when using the
RS-485 connector).
Please refer to the chart for each address (0 to
127) DIP switches settings.
œ
Switch 1 is the least significant bit (LSB) and
switch 7 the most significant bit (MSB) (Down: 0,
Up: 1)
Example:
œ
If the address is 1, set switch 1 to the ON side
(up)
œ
If the address is 10, set switches 2 and 4 to the
ON side (up)
œ
If the address is 127, set all the switches to the
ON side (up)
8: Available (Not used)
9: To select the connector used. [232] side (down) for
RS-232C, [485] side (up) for RS-485.
10: To setup the termination (only when using the
RS-485 connector).
OFF side (down): Not terminated
ON side (up): Terminated
NOTE:
œ
Refer to the RS-232C and RS-485 command section or
to the special controller and/or to the computer
instruction manual.
Address
DIP switch
(1:ON side, 0:OFF side)
Address
DIP switch
(1:ON side, 0:OFF side)
1
2
3
4
5
6
7
1
2
3
4
5
6
7
0
0
0
0
0
0
0
0
64
0
0
0
0
0
0
1
1
1
0
0
0
0
0
0
65
1
0
0
0
0
0
1
2
0
1
0
0
0
0
0
66
0
1
0
0
0
0
1
3
1
1
0
0
0
0
0
67
1
1
0
0
0
0
1
4
0
0
1
0
0
0
0
68
0
0
1
0
0
0
1
5
1
0
1
0
0
0
0
69
1
0
1
0
0
0
1
6
0
1
1
0
0
0
0
70
0
1
1
0
0
0
1
7
1
1
1
0
0
0
0
71
1
1
1
0
0
0
1
8
0
0
0
1
0
0
0
72
0
0
0
1
0
0
1
9
1
0
0
1
0
0
0
73
1
0
0
1
0
0
1
10
0
1
0
1
0
0
0
74
0
1
0
1
0
0
1
11
1
1
0
1
0
0
0
75
1
1
0
1
0
0
1
12
0
0
1
1
0
0
0
76
0
0
1
1
0
0
1
13
1
0
1
1
0
0
0
77
1
0
1
1
0
0
1
14
0
1
1
1
0
0
0
78
0
1
1
1
0
0
1
15
1
1
1
1
0
0
0
79
1
1
1
1
0
0
1
16
0
0
0
0
1
0
0
80
0
0
0
0
1
0
1
17
1
0
0
0
1
0
0
81
1
0
0
0
1
0
1
18
0
1
0
0
1
0
0
82
0
1
0
0
1
0
1
19
1
1
0
0
1
0
0
83
1
1
0
0
1
0
1
20
0
0
1
0
1
0
0
84
0
0
1
0
1
0
1
21
1
0
1
0
1
0
0
85
1
0
1
0
1
0
1
22
0
1
1
0
1
0
0
86
0
1
1
0
1
0
1
23
1
1
1
0
1
0
0
87
1
1
1
0
1
0
1
24
0
0
0
1
1
0
0
88
0
0
0
1
1
0
1
25
1
0
0
1
1
0
0
89
1
0
0
1
1
0
1
26
0
1
0
1
1
0
0
90
0
1
0
1
1
0
1
27
1
1
0
1
1
0
0
91
1
1
0
1
1
0
1
28
0
0
1
1
1
0
0
92
0
0
1
1
1
0
1
29
1
0
1
1
1
0
0
93
1
0
1
1
1
0
1
30
0
1
1
1
1
0
0
94
0
1
1
1
1
0
1
31
1
1
1
1
1
0
0
95
1
1
1
1
1
0
1
32
0
0
0
0
0
1
0
96
0
0
0
0
0
1
1
33
1
0
0
0
0
1
0
97
1
0
0
0
0
1
1
34
0
1
0
0
0
1
0
98
0
1
0
0
0
1
1
35
1
1
0
0
0
1
0
99
1
1
0
0
0
1
1
36
0
0
1
0
0
1
0
100
0
0
1
0
0
1
1
37
1
0
1
0
0
1
0
101
1
0
1
0
0
1
1
38
0
1
1
0
0
1
0
102
0
1
1
0
0
1
1
39
1
1
1
0
0
1
0
103
1
1
1
0
0
1
1
40
0
0
0
1
0
1
0
104
0
0
0
1
0
1
1
41
1
0
0
1
0
1
0
105
1
0
0
1
0
1
1
42
0
1
0
1
0
1
0
106
0
1
0
1
0
1
1
43
1
1
0
1
0
1
0
107
1
1
0
1
0
1
1
44
0
0
1
1
0
1
0
108
0
0
1
1
0
1
1
45
1
0
1
1
0
1
0
109
1
0
1
1
0
1
1
46
0
1
1
1
0
1
0
110
0
1
1
1
0
1
1
47
1
1
1
1
0
1
0
111
1
1
1
1
0
1
1
48
0
0
0
0
1
1
0
112
0
0
0
0
1
1
1
49
1
0
0
0
1
1
0
113
1
0
0
0
1
1
1
50
0
1
0
0
1
1
0
114
0
1
0
0
1
1
1
51
1
1
0
0
1
1
0
115
1
1
0
0
1
1
1
52
0
0
1
0
1
1
0
116
0
0
1
0
1
1
1
53
1
0
1
0
1
1
0
117
1
0
1
0
1
1
1
54
0
1
1
0
1
1
0
118
0
1
1
0
1
1
1
55
1
1
1
0
1
1
0
119
1
1
1
0
1
1
1
56
0
0
0
1
1
1
0
120
0
0
0
1
1
1
1
57
1
0
0
1
1
1
0
121
1
0
0
1
1
1
1
58
0
1
0
1
1
1
0
122
0
1
0
1
1
1
1
59
1
1
0
1
1
1
0
123
1
1
0
1
1
1
1
60
0
0
1
1
1
1
0
124
0
0
1
1
1
1
1
61
1
0
1
1
1
1
0
125
1
0
1
1
1
1
1
62
0
1
1
1
1
1
0
126
0
1
1
1
1
1
1
63
1
1
1
1
1
1
0
127
1
1
1
1
1
1
1
1
2
3
4
5
6
7
8
9
10
ON
ADDRESS
ON
OFF
485
232
TERMINATE
ON
OFF
RD2QD/NA (DTL-4800 GB) Tue. Aug., 08/2000
46
English