SAVING (COPYING) RECORDED IMAGES
Reading data from a DDS (DAT) drive into the archive area
Note: All of the previously recorded images in the archive area are deleted when images are transferred in this way.
Press the COPY button during recording or when the
digital video recorder is stopped.
The ARCHIVE SET screen appears.
Use the jog dial to select RESTORE and then turn the
shuttle dial clockwise.
The message “LISTING DATA !” appears. When playback is complete, the
RESTORE FROM DDS (DAT) screen appears.
Use the jog dial to select the data to be read into the
archive area, and then turn the shuttle dial clockwise.
Reading of data starts. The RESTORE FROM DDS (DAT) screen appears.
The image data on the DDS (DAT) drive is then saved into the archive area.
When all data has been read into the archive area, “RESTORE FINISHED!”
appears.
When you play back the images in the archive area, the image data that has
been read can be played back.
COPY
1
<ARCHIVE SET>
BACK UP ->
RESTORE ->
ERASE ->
2
01-01-01
08:00:00 EN 0.12SEC
LISTING DATA !
<PRESS COPY TO ABORT>
3
<RESTORE FROM DDS(DAT)>
NO DATE TIME SIZE
0001 13-12-2001 11:13 3.0GB
0002 15-12-2001 10:15 2.0GB
0003 17-12-2001 10:15 2.0GB
STORED DATA ON HDD WILL BE ERASED !
01-01-01
08:00:00 EN 0.12SEC
RESTORING FROM DDS(DAT) !
<PRESS COPY TO ABORT>
36