31
S4359249
4.
Remove the 1/2" flare nut from the optional tube
connection (C), place it on the cut wide tube, and
then flare the wide tube. (Fig. 3-76)
5.
Connect the optional tube connection (C) to the
wide tube.
6.
Connect the 3/4" tube to the connected optional
tube connection.
7.
Connect the 3/8" tube to the narrow tube.
8.
Cover the narrow and wide tubes with insulation
material.
9.
Make a 3-3/16" hole in the wall, centered on the
crossing point between the triangle marks (A'
and B') on the rear panel. (Fig. 3-75)
10. Connect the 3/4" tube to the wide tube.
11. Connect the 3/8" tube to the narrow tube.
12. Cover the narrow and wide tubes with insulation
material.
Outdoor Unit Tubing
1.
Connect a wide tube (3/4") to the wide tube
valve.(Fig. 3-77)
2.
Connect the tube assy, which was packed in the
indoor unit carton, to the narrow tube valve.
3.
Before attaching the tube assy to the mounting
valve, wrap the supplied packing A (3/4"
×
1-3/8"
×
T3/16") onto the 5/16" tube of the tube assy to
avoid direct contact of the tube assy with the
mounting valve. (Fig. 3-78, 3-79)
4.
Similarly arrange the supplied packing B (2-3/8"
×
1-3/16"
×
T3/16") on the mounting valve. (Fig.
3-78, 3-79)
5.
Insert clamp Ain the extracted round hole (3/16")
on the mounting valve, and bind the tube assy
and packing A. (Fig. 3-78)
6.
Insert clamp B in the square hole of the mounting
valve, and bind it so the tube assy is in contact
with packing B. (Fig. 3-79)
7.
Connect the narrow tube (3/8") between the
units. When tightening the flare nut, use the
double-wrench method. (Torque: 300 to 340
lbs.·in) (Fig. 3-80)
8.
After completing the tubing work, check that the
tube assy is not in direct contact with the 3/4"
tube.
KS2432A
(Rear-right tubing)
Fig. 3-76
2251_T_I
4. Flare wide tube
3. Cut wide tube
5. Connect tube
assy
Optional tube
connection (C) 1/2"
(Optional part)
Narrow
tube 3/8"
6. Connect
wide tube
3/4"
7. Connect
narrow tube
3/8"
Fig. 3-77
2252_T_I
Mounting valve
Packing B
Packing A
Clamp
Narrow tube (3/8")
Wide tube (3/4")
Wide tube valve
Narrow tube valve
Tube assy
Clamp B
Clamp A
Packing B
Packing A
3/16" hole
2253_T_I
Clamp B
Clamp A
Square hole
Packing B
Packing A
2254_T_I
Fig. 3-79
Fig. 3-78
Tube assy
Narrow tube
2255_T_I