TROUBLE
INSPECTION
CAUSES
REMEDY
d. Drain
Foreign matter in Valve
Clean valve inside
Water does not
drain out
Is the Magnetic coil
working normally ?
Valve Spring is deformed
Replace Valve Spring
No
Valve Bellows is
deformed
Replace Valve Bellow
or replace Valve
Spring
Magnetic Coil lead wire
is disconnected.
Repair or replace
P.C.B Complete is
defective
Replace
Drain takes time
too long
Valve Bellow is deformed
Replace
Connect Hose is deformed
Repair or replace
Drain Hose Ass y is
deformed
Repair
Extension hose is too
long or too high.
Repair
e. Spin Drying
Spin drying cycle
does not work
Does safety device
work ?
Machine inclines
Adjust the adjustor of
leg
No
The V-belt is slipping
Adjust the motor
position
V-belt is snapped
Replace
Motor Pulley mounting
screw is loose.
Tighten up
Motor is disconnected or
burnt
Repair or replace
Capacitor is defective or
disconnected
Repair or replace
Bearing Ass y is
defective
Replace
Magnetic Coil is defective
Replace
Brake Lever is defective
Replace
Thermostat on motor is
opened
Repair or replace
after cooling down
Poor connection of the 14
pin connectors
Repair or replace
P.C.B Complete is
defective
Replace
Yes
NOTE :
1. When Safety Switch is continuously
affected 3 times, the washer will adjust
the unbalance condition. If the washer
can not adjust the unbalance condition,
it will stop and indicator shows U3 by
flashing on and off.
1m max (extension)
Extension hose height
Extension hose lenght
15 cm max
1m max
- -
3m max
Extension of the Drain Hose:
The maximum length and height to which the
Drain Hose can be extended are given below.
1
5
c
m
m
a
x
Yes