- 12 -
11. Care of service :
Removing Front Panel
(1) Take two fixing screws out.
(2) Pull Front Panel down and lift it up for taking out.
(3) Reverse the order of the steps above to put the unit back.
Replacing Control Plate and Printed Circuit Board
(1) Follow the steps (1) to (2) of the Replacing Front Panel .
(2) Pull stopping pin down for taking out.
(3) Slide the control plate approximately 7mm to the left.
(4) Hold both edges of the Control Plate, lift and tilt it towards back.
(5) Take out 6 screws that are holding the PCB, and remove the 9P, 4P, 3P and 2P
connectors before removing the PCB.
(6) Reverse the order of the steps above to put the unit back.
Removing Back Plate
(1) Remove the Cap on drainage and then remove screws.
(2) Hold both ends of the Back Plate, lift and remove it.
(3) Once the Back Plate is removed, the water supply valve and safety switch can be replaced.
(4) When the parts are replaced, reverse the order of the steps above to put the unit back.
Disconnect the power cord during servicing for your safety.