MAINTENANCE
5-11
SY500H Excavator OMM
• Inspect and clean the radiator, hydraulic oil cooler, and
condenser fins. (See page 5-20.)
• Replace the secondary fuel filter. (See page 5-29.)
• Replace the fuel filter water separator element. (See
• Replace the engine air filter. (See page 5-13.)
• Replace the hydraulic tank breather filter element. (See
• Replace the cab fresh-air filter. (See page 5-22.)
• Collect an engine oil sample. (See page 5-14.)
• Collect a hydraulic oil sample. (See page 5-32.)
• Collect a final drive oil sample (both). (See page 5-47.)
• Replace the final drive oil. (See page 5-48.)
Every 6 Months or 1000 Hours
NOTE:
Make sure all daily, 50-hour, 100-hour, 250-hour,
and 500-hour maintenance tasks have been
completed before proceeding with the 1000-hour
maintenance tasks.
• Pressure-wash and clean the entire machine. Do a
complete machine structural inspection.
• Check the fuel tank strainer. (See page 5-28.)
• Check the fuel lines for leaks or damage. Replace as
necessary.
• Check the accumulator function. (See page 5-30.)
• Clean the hydraulic oil suction strainer. (See
• Replace the hydraulic tank return filter. (See
• Replace the hydraulic oil pilot filter element. (See
• Replace the hydraulic case drain filter element. (See
Annually or Every 2000 Hours
NOTE:
Make sure all daily, 50-hour, 100-hour, 250-hour,
and 1000-hour maintenance tasks have been
completed before proceeding with the 2000-hour
maintenance tasks.
• Check the alternator. (See page 5-17.)
• Check the starter. (See page 5-17.)
• Check the engine valve clearance. (Contact a SANY
dealer for more information.)
• Replace the hydraulic oil. (See page 5-35.)
• Replace the engine coolant. (See page 5-18.)
• Replace the final drive oil. (See page 5-48.)
Hydraulic Breaker Maintenance
Interval
Hydraulic oil breaks down faster on machines equipped
with a hydraulic breaker than on machines equipped with
a bucket.
Change the hydraulic oil and filters every 400 hours on
breaker-equipped machines.
NOTICE!
The hydraulic oil filter must be replaced after 250
hours with a breaker operating rate above 50%.
See “Replace the Hydraulic Oil” on page 5-35.
After Maintenance is Completed
Record the completion of all of the maintenance tasks in
the Maintenance Log. If authorized, remove all
lockout/tagout warnings and machine-securing elements
and fully activate the machine. Return the machine to
operation.
Содержание SY500H
Страница 2: ...Page Intentionally Blank ...
Страница 14: ...5 10 SY500H Excavator OMM Page Intentionally Blank ...
Страница 30: ...2 8 SAFETY SY500H Excavator OMM Page Intentionally Blank ...
Страница 70: ...3 40 MACHINE CONTROLS SY500H Excavator OMM Page Intentionally Blank ...
Страница 172: ...5 64 MAINTENANCE SY500H Excavator OMM Page Intentionally Blank ...
Страница 174: ...6 2 SPECIFICATIONS SY500H Excavator OMM Machine Dimensions 0000837 Figure 6 1 1 2 3 4 5 6 7 8 9 10 11 ...
Страница 180: ...6 8 SPECIFICATIONS SY500H Excavator OMM Page Intentionally Blank ...
Страница 194: ...I 8 SY500H Excavator OMM Page Intentionally Blank ...
Страница 195: ...Page Intentionally Blank ...