Check the Stationary Regeneration
NOTE:
Perform this procedure to activate the
stationary exhaust cleaning system when the
yellow Diesel Particulate Filter icon (1) on the
monitor home screen is either on or flashing,
or if the yellow Check Engine icon (2) on the
monitor home screen is on, each of which
indicate increasing levels of soot buildup in
the exhaust system. This occurs after
continued operation with the Regeneration
Inhibit switch set to the ON position and its
icon displays (3).
1. Prepare the machine for service. See “Maintenance Safety” on page 2-8.
2. Make sure the machine is in a safe location where the
exhaust pipe outlet will not face any combustible
materials.
3. Make sure both the DEF and fuel tanks are full, as shown by their indicators on the monitor home screen.
4. Place the hydraulic lockout lever in the closed (locked)
position.
NOTICE!
If the red Stop Engine icon (4) illuminates, shut down the engine as soon as it is safe to do so
and immediately contact SANY to arrange for service support. Failure to so could result in
engine damage.
CAUTION!
The engine exhaust will be very hot. Make sure
that the machine is not in a combustible area.
Failure to follow this caution could result in
injury.