6. Remove the old DEF tank filter (4) and replace it with a
new filter.
7. Install the DEF sending unit (3) in the DEF tank.
8. Install the fasteners to secure the DEF sending unit (3)
to the tank.
9. Connect the DEF and engine coolant hoses.
10. Connect the DEF sending unit electrical connector (2).
11. Remove the DEF tank cap (5), then add DEF through
the filler neck as needed.
12. Install the DEF tank cap (5), then close the DEF
compartment door.
Fig. 5-34