— 5 —
Actual input value
Reading
DC 30.00V
DC 0.00V
DC 35.00V
DC 5.00V
DC 25.00V
DC - 5.00V
button
Power switch &
function switch
--- measuring terminal
+ measuring terminal
button
(Range hold)
button
(Relative value measurement)
button
(Data hold)
When the button is pressed,
the functions change as follows:
Position:
→
→
→
Slide this switch to turn on and off the
power and to select a function.
Insert the black test lead.
Insert the red test lead.
When this button is pressed, the meter will be
set in the manual mode and the range is fixed.
(“ ” will disappear from the display.) In the
manual mode, each time this button is pressed,
the range changes. While checking the unit and
decimal point on the display, select the best
range. To return to the auto range, hold this
button pressed for 1 second or longer. (“ ”
will appear on the display.)
When this button is pressed,“ ” will appear on the
display and the input value when this is pressed
will be set to 0. To reset, press this button again.
(“
” will disappear from the display.)
Example: Indication after pressing this button
when 30.00 VDC is input:
When this button is pressed, the value indicated will
be held. (“
” will appear on the display.) The
indicated value will not change if the measurement
input fluctuates. When this button is pressed again,
the hold status will be canceled and the meter will
return to the normal measurement mode. (“ ” will
disappear from the display.)